MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3174/ajnr.a8082

Медицинская библиотека · AJNR. American journal of neuroradiology · 2023

Lateral Decubitus Dynamic CT Myelography with Real-Time Bolus Tracking (dCTM-BT) for Evaluation of CSF-Venous Fistulas: Diagnostic Yield Stratified by Brain Imaging Findings.

Huynh Thien J, Parizadeh Donna, Ahmed Ahmed K, Gandia Christopher T, Davison Hal C, Murray John V, Mark Ian T, Madhavan Ajay A, Shlapak Darya, Rozen Todd D, Brinjikji Waleed, Vibhute Prasanna, Gupta Vivek, Brewer Kacie, Fermo Olga

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: CSF-venous fistulas (CVFs) associated with spontaneous intracranial hypotension (SIH) may have a transient appearance, relative to contrast arrival, which may influence the diagnostic performance of lateral decubitus CT myelography (CTM). We developed a dynamic CTM protocol using real-time bolus-tracking (dCTM-BT) to improve the temporal resolution and standardize the timing of CTM acquisitions post-intrathecal contrast administration. The purpose of our study was to evaluate the feasibility of the dCTM-BT technique and evaluate its diagnostic yield for CVF detection, stratified by brain MRI SIH findings.

MATERIALS AND

METHODS

Patients with suspected SIH without extradural fluid collection on spine MRI who underwent dCTM-BT were retrospectively reviewed. CT bolus monitoring was performed at the upper thoracic level. Following the visualization of dense intrathecal contrast, at least 3 CTM acquisitions of the spine were obtained and reviewed by 2 neuroradiologists. The Bern SIH score was calculated on the brain MRI. The diagnostic yield for CVF detection was evaluated, stratified by Bern score categories and a receiver operating characteristic (ROC) analysis.

RESULTS

Out of 48 patients, 23 (48%) had a CVF on dCTM-BT, located at T1-5 (n = 4), T6-12 (n = 18), L1 (n = 1), with 70% on the right. CVF was identified in 22/22 (100%) of patients who had a high Bern score, 1/7 (14%) of those who had an intermediate score, and 0/19 (0%) of those who had a low score. The area under the ROC curve was 0.99 (95% CI, 0.98-1.00). The optimal cutoff was a Bern score of ≥5 (96% sensitivity, 100% specificity).

CONCLUSIONS

dCTM-BT is feasible and has excellent diagnostic performance for CVF identification/localization. The Bern score is strongly associated with CVF detection and may help inform who will benefit from dCTM-BT.

Для цитирования: Huynh Thien J, Parizadeh Donna, Ahmed Ahmed K, Gandia Christopher T, Davison Hal C, Murray John V, Mark Ian T, Madhavan Ajay A, Shlapak Darya, Rozen Todd D, Brinjikji Waleed, Vibhute Prasanna, Gupta Vivek, Brewer Kacie, Fermo Olga. Lateral Decubitus Dynamic CT Myelography with Real-Time Bolus Tracking (dCTM-BT) for Evaluation of CSF-Venous Fistulas: Diagnostic Yield Stratified by Brain Imaging Findings.. AJNR. American journal of neuroradiology. 2023. DOI: 10.3174/ajnr.a8082.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.