Transesophageal echocardiography for incremental value of Amplatezer cribriform septal occluder for percutaneous transcatheter closure of complex septal defects: Case series.

Tsai Shen Kou, Hsiung Ming C, Wei Jeng, Lee Yang-Tsai, Yu Ho-Ping, Ou Ching-Huei, Yin Wei-Hsian

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The anatomy of septal defects can be complex and morphologically unpredictable. Balloon sizing of such defects may not be feasible, and an appropriately sized commercial occluder may not be available. Therefore, percutaneous transcatheter closure of such defects can be challenging because of an increased risk of complications. In this study, we have described the efficacy and safety of transcatheter closure of complex septal defects using Amplatzer cribriform occluder devices, assessed by real time three-dimensional (RT 3D) color Doppler transesophageal echocardiography (TEE).

METHODS AND

RESULTS

Four complex septal defects were involved in this investigation: (1) reimplanted multiple atrial septal defects (ASD) with one device embolization; (2) postinfarction ventricular septal defect; (3) long tunnel patent foramen ovale; and (4) postoperative residual ASD. All patients underwent percutaneous transcatheter interventions due to the high risk of surgical complications, and one of the three available cribriform ASD device sizes (18 mm, 25 mm, or 35 mm) was implanted. Perioperative RT 3D TEE combined with fluoroscopy was used for monitoring during the procedure. All defects were successfully occluded by cribriform septal occluder devices using the transcatheter technique.

CONCLUSION

Our patients with complex septal defects were successfully treated by transcatheter closure using an Amplazter cribriform septal occluder device with careful planning based on patient presentation and close interdisciplinary collaboration. RT 3D color Doppler TEE provided precise information for the selection of the appropriate occluder device and facilitated the procedure by guiding the catheter through the often challenging patient anatomy.

Для цитирования: Tsai Shen Kou, Hsiung Ming C, Wei Jeng, Lee Yang-Tsai, Yu Ho-Ping, Ou Ching-Huei, Yin Wei-Hsian. Transesophageal echocardiography for incremental value of Amplatezer cribriform septal occluder for percutaneous transcatheter closure of complex septal defects: Case series.. Journal of the Chinese Medical Association : JCMA. 2017. DOI: 10.1016/j.jcma.2017.03.003.