Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2014
External fixation versus volar locking plate for displaced intra-articular distal radius fractures: a prospective randomized comparative study of the functional outcomes.
Сравнительное исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Shukla Rajeev, Jain Ravi Kant, Sharma Neeraj K, Kumar Ravindra
Аннотация
BACKGROUND: The objective of the study was to compare the efficacy of external fixation and volar plating on the functional parameter of displaced intra-articular (Cooney's type IV) distal end radius fractures using the Green and O'Brien scoring system.
MATERIALS AND METHODS: This prospective randomized study comprised 68 patients treated with external fixation and 42 patients treated with volar locking plates. The patients were followed up at 6 months and 1 year after surgery. The assessment of pain, range of motion, grip strength and activity were assessed at each follow-up visit and scored according to the Green and O'Brien scoring system.
RESULTS: At 1 year after surgery, we observed that external fixation showed significantly better results than volar locking plates using the Green and O'Brien scores for range of motion (22.0 ± 4.77 vs 19.89 ± 5.05), grip strength (19.91 ± 5.4 vs 16.89 ± 4.4) and final outcome (87.36 ± 11.62 vs 81.55 ± 11.32). No difference was found in pain and activity between these two groups of patients. Patients aged <50 years treated with external fixation showed excellent results (final score (91.57 ± 9.01) at 1 year follow-up.
CONCLUSION: External fixation showed superiority over volar locked plating after 1 year of surgery.
LEVEL OF EVIDENCE: IV.
MATERIALS AND METHODS: This prospective randomized study comprised 68 patients treated with external fixation and 42 patients treated with volar locking plates. The patients were followed up at 6 months and 1 year after surgery. The assessment of pain, range of motion, grip strength and activity were assessed at each follow-up visit and scored according to the Green and O'Brien scoring system.
RESULTS: At 1 year after surgery, we observed that external fixation showed significantly better results than volar locking plates using the Green and O'Brien scores for range of motion (22.0 ± 4.77 vs 19.89 ± 5.05), grip strength (19.91 ± 5.4 vs 16.89 ± 4.4) and final outcome (87.36 ± 11.62 vs 81.55 ± 11.32). No difference was found in pain and activity between these two groups of patients. Patients aged <50 years treated with external fixation showed excellent results (final score (91.57 ± 9.01) at 1 year follow-up.
CONCLUSION: External fixation showed superiority over volar locked plating after 1 year of surgery.
LEVEL OF EVIDENCE: IV.
Предметные рубрики MeSH
AdultBone PlatesExternal FixatorsFemaleFracture Fixation, InternalFracture HealingHumansInjury Severity ScoreIntra-Articular FracturesMaleMiddle AgedProspective StudiesRadiographyRadius FracturesRange of Motion, ArticularRecovery of FunctionRisk AssessmentTensile StrengthTreatment OutcomeWrist Injuries