MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2014.12.002

Медицинская библиотека · Biosensors & bioelectronics · 2014

A competitive photoelectrochemical assay for estradiol based on in situ generated CdS-enhanced TiO2.

Li Rongxia, Liu Yixin, Yan Tao, Li Yueyun, Cao Wei, Wei Qin, Du Bin

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A novel and simple photoelectrochemical (PEC) bioassay protocol for estradiol was proposed based on in situ generated CdS-enhanced TiO2 film via competitive strategy. The CdS was generated in situ by immediately dropping S(2-) onto the Cd(2+)-functionalized titanium phosphate nanoparticles (TiP@Cd(2+)). The TiO2 photoactive sensing film with countless active sites was obtained by calcination and further explored for estradiol (E2) capture. The TiP@Cd(2+) was used as labels and immobilized through affinity-specific binding with E2 on the surface of the electrode. Greatly enhanced sensitivity was achieved by using porous TiP nanoparticles as carriers to load a large amount of Cd(2+) and further for more CdS production through the S(2-) deposition. What's more, the photocurrent of CdS generated on the electrode surface could be significantly amplified by the coupling of CdS and TiO2, which could enhance the excitation and photo-to-electric conversion efficiency. Through the application of a competitive binding assay, the proposed biosensor showed high sensitivity with a detection limit down to 2pg/mL. This simple and fast PEC E2-sensing approach offers great promise to extend its application for the assay of small molecules of biomedical, food and environmental interest. Additionally, the strategy of employing in situ generated narrow-band gap semiconductors paves a new way for PEC sensing.

Для цитирования: Li Rongxia, Liu Yixin, Yan Tao, Li Yueyun, Cao Wei, Wei Qin, Du Bin. A competitive photoelectrochemical assay for estradiol based on in situ generated CdS-enhanced TiO2.. Biosensors & bioelectronics. 2014. DOI: 10.1016/j.bios.2014.12.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.