m+Medelevator.RU
← Поиск публикаций
Journal of cardiology · 2015

Clinical and angiographic outcomes of paclitaxel-eluting coronary stent implantation in hemodialysis patients: A prospective multicenter registry: The OUCH-TL study (outcome in hemodialysis of TAXUS Liberte).

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kozuma Ken, Otsuka Masaya, Ikari Yuji, Uehara Yoshiki, Yokoi Hiroyoshi, Sano Koichi, Tanabe Kengo, Hibi Kiyoshi, Yamane Masahisa, Ishiwata Sugao, Ohta Hiroshi, Yamauchi Yasutaka, Suematsu Nobuhiro, Nakayama Mio, Inoue Naoto, Kyono Hiroyuki, Suzuki Nobuaki, Isshiki Takaaki

Аннотация

BACKGROUND: The outcome of percutaneous coronary intervention (PCI) has been reported to be poor in hemodialysis (HD) patients even in the drug-eluting stent era. We have reported relatively poor outcomes after sirolimus-eluting stent implantation in the OUCH study.

METHODS: The OUCH-TL study is a prospective, non-randomized, single-arm registry designed to assess the results of paclitaxel-eluting stent (PES) in HD patients with follow-up quantitative coronary angiography analysis. The primary endpoint was the occurrence of target-vessel failure (TVF) defined as cardiac death, myocardial infarction (MI), and target-vessel revascularization (TVR) at 12 months.

RESULTS: A total of 119 patients with 154 lesions were enrolled (one withdrawal). Mean age was 65±10 years, male gender was 79%, 89% of cases had stable coronary disease. Diabetic nephropathy was diagnosed in 61% of the patients. American College of Cardiology/American Heart Association type B2/C accounted for 96% of lesions and 22.7% of lesions were treated with Rotablator (Boston Scientific Corporation, Natick, MA, USA). Rates of TVF, death, MI, stent thrombosis and TVR at 12 months were 20.2%, 5.9%, 5.0%, 1.4%, and 12.6%, respectively. TVR was performed in 8.4% of the patients up to 12 months. Late loss in-stent was 0.48±0.61mm, and late loss in-segment was 0.37±0.61mm at 9 months. Binary restenosis in-stent was 10.3% and in-segment was 14.5%.

CONCLUSIONS: Outcomes of PES implantation in hemodialysis patients appears comparable to those of non-hemodialysis patients.