DOI 10.1097/oi9.0000000000000167
Hip resection arthroplasty for acute femoral neck fractures in the non-ambulator.
Аннотация
OBJECTIVES
Hemiarthroplasty (HA) is the current standard of care for displaced femoral neck fractures (FNFs) in non-ambulators. Despite excellent outcomes, arthroplasty-specific risks remain, including dislocation, implant failure, periprosthetic fracture and infection, and fat embolization syndrome. To eliminate the possibility of these complications, should non-ambulatory patients with acute, native hip FNFs be treated with simple hip resection arthroplasty (HRA) instead of HA?
DESIGN
Retrospective case series.
SETTING
Large, urban level-1 trauma center.
PATIENTS/
PARTICIPANTS
Five non-ambulatory patients (6 hips) with acute, native hip FNF underwent femoral head and neck resection. Also, the most recent 10 FNFs treated with HA were also identified for comparison purposes.
INTERVENTION: HRA was performed via a Smith-Peterson approach with an oscillating saw or osteotome to complete the fracture or perform a fresh neck cut.
MAIN OUTCOME MEASUREMENTS: Outcomes included postoperative vs preoperative VAS pain scores and narcotics usage, and return to baseline functional status (sit up in bed or a chair postoperatively). Procedure time for HRA was compared with the 10 most recent patients with FNF treated with HA.
RESULTS
HRA resulted in decreased postoperative vs preoperative VAS pain scores (7.7 vs 3.3, P = .002), and decreased operative times (59.2 minutes for HRA, 111.8 minutes for HA, P < .001). All HRA patients had immediate return of baseline function.
CONCLUSION
HRA offers shorter operative times when compared with HA, decreased postoperative VAS pain scores, and immediate return to functional baseline status without possibility of arthroplasty-specific complications. HRA may be an acceptable treatment option for FNFs in the non-ambulator.Level of evidence: IV.