BACKGROUND

This study aimed to compare targeted next-generation sequencing (tNGS) with metagenomic next-generation sequencing (mNGS) for pathogen detection in infants with severe postoperative pneumonia after congenital heart surgery.

METHODS

We conducted a retrospective observational study using data from the electronic medical record system of infants who developed severe pneumonia after surgery for congenital heart disease from August 2021 to August 2022. Infants were divided into tNGS and mNGS groups based on the pathogen detection methods. The primary outcome was the efficiency of pathogen detection, and the secondary outcomes were the timeliness and cost of each method.

RESULTS

In the study, 91 infants were included, with tNGS detecting pathogens in 84.6% (77/91) and mNGS in 81.3% (74/91) of cases (P = 0.55). No significant differences were found in sensitivity, specificity, PPA, and NPA between the two methods (P > 0.05). tNGS identified five strains with resistance genes, while mNGS detected one strain. Furthermore, tNGS had a faster detection time (12 vs. 24 h) and lower cost ($150 vs. $500) compared to mNGS.

CONCLUSION

tNGS offers similar sensitivity to mNGS but with greater efficiency and cost-effectiveness, making it a promising approach for respiratory pathogen detection.

Для цитирования: Zheng Yi-Rong, Chen Xiu-Hua, Chen Qiang, Cao Hua. Comparison of targeted next-generation sequencing and metagenomic next-generation sequencing in the identification of pathogens in pneumonia after congenital heart surgery: a comparative diagnostic accuracy study.. Italian journal of pediatrics. 2024. DOI: 10.1186/s13052-024-01749-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.