MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2018.08.015

Медицинская библиотека · Heart rhythm · 2018

Continuous monitoring after second-generation cryoballoon ablation for paroxysmal atrial fibrillation in patients with cardiac implantable electronic devices.

Choudhury Rajin, Coutino Hugo-Enrique, Darciuc Radu, Ströker Erwin, De Regibus Valentina, Mugnai Giacomo, Paparella Gaetano, Terasawa Muryio, Varnavas Varnavas, Salghetti Francesca, Iacopino Saverio, Takarada Ken, Abugattas Juan-Pablo, Sieira Juan, Brugada Pedro, de Asmundis Carlo, Chierchia Gian-Battista

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The second-generation cryoballoon (CB) is effective in achieving pulmonary vein isolation. Continuous monitoring would eliminate any over- or underestimated freedom from atrial fibrillation (AF) postablation.

OBJECTIVE

The purpose of this study was to differentiate between arrhythmias occurring after cryoballoon ablation (CBA), detecting true AF in symptomatic patients and detecting silent subclinical AF.

METHODS

Between June 2012 and January 2015, 54 patients with a preexisting cardiac implantable electronic device (CIED) who had undergone CBA for paroxysmal atrial fibrillation (PAF) were included in our retrospective study. Regular CIED controls, physical examination, and ECG recordings were performed by an experienced cardiologist blinded to the ablation procedure. Data on any hospitalization during follow-up were gathered. Patients were encouraged to note all clinical symptoms during follow-up.

RESULTS

Continuous monitoring showed a success rate of 83.3% after 1 year and 75.93% after 3 years of follow-up. During the first year, 68% of episodes of palpitations after ablation were due to sinus tachycardia, nonsustained ventricular tachycardia, or supraventricular tachycardia. AF recurrence was detected in 15.6% of asymptomatic patients during follow-up. Total AF burden post-CBA had decreased to 0.64% ± 4.34% (P <.001) during long-term follow-up of 3.3 years.

CONCLUSION

Although this is a selected group of patients with a preexisting CIED, continuous monitoring showed freedom from AF in 83.3% of patients post-CBA after 1 year and 75.93% after 3 years of follow-up.

Для цитирования: Choudhury Rajin, Coutino Hugo-Enrique, Darciuc Radu, Ströker Erwin, De Regibus Valentina, Mugnai Giacomo, Paparella Gaetano, Terasawa Muryio, Varnavas Varnavas, Salghetti Francesca, Iacopino Saverio, Takarada Ken, Abugattas Juan-Pablo, Sieira Juan, Brugada Pedro, de Asmundis Carlo, Chierchia Gian-Battista. Continuous monitoring after second-generation cryoballoon ablation for paroxysmal atrial fibrillation in patients with cardiac implantable electronic devices.. Heart rhythm. 2018. DOI: 10.1016/j.hrthm.2018.08.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.