BACKGROUND

We used three-dimensional (3-D) computed tomography to develop a novel supraclavicular approach to the subclavian vein that minimizes the distance from insertion site to the vein.

METHODS

Forty-five adult patients with normal body build were retrospectively included in the 3-D computed tomography investigation. Assuming that the clavisternomastoid angle was the skin entry point, and that the subclavian vein on the first rib was a target, the optimal angle of approach was measured on the simulated 3-D images. A 3-D video was developed from these images to explain the approach. In a pilot study, we prospectively tested this approach in 60 adult patients with normal body build requiring central venous catheterization. The number of attempts, success rate, and complications were noted.

RESULTS

The optimal angle of approach was 10.6 degrees +/- 5.3 degrees medially and 35.4 degrees +/- 12.5 degrees posteriorly from the skin entry point. The estimated depth of the subclavian vein was 13.7 +/- 3.1 mm. During the pilot study, the first trial with a finder needle was successful in 87% of patients and the overall success rate of catheterizations was 100% without complications.

CONCLUSIONS

The proposed supraclavicular approach to the subclavian vein is a simple method of central venous catheterization. The pilot study suggests the method is reasonably safe. The video explaining the approach graphically is available in the supplementary material.

Для цитирования: Jung Chul-Woo, Seo Jeong-Hwa, Lee Whal, Bahk Jae-Hyon. A novel supraclavicular approach to the right subclavian vein based on three-dimensional computed tomography.. Anesthesia and analgesia. 2007. DOI: 10.1213/01.ane.0000266469.63098.38.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.