MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-019-48290-2

Медицинская библиотека · Scientific reports · 2019

CdS quantum dots-based immunoassay combined with particle imprinted polymer technology and laser ablation ICP-MS as a versatile tool for protein detection.

Vaneckova Tereza, Bezdekova Jaroslava, Tvrdonova Michaela, Vlcnovska Marcela, Novotna Veronika, Neuman Jan, Stossova Aneta, Kanicky Viktor, Adam Vojtech, Vaculovicova Marketa, Vaculovic Tomas

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

For the first time, the combination of molecularly imprinted polymer (MIP) technology with laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is presented with focus on an optimization of the LA-ICP-MS parameters such as laser beam diameter, laser beam fluence, and scan speed using CdS quantum dots (QDs) as a template and dopamine as a functional monomer. A non-covalent imprinting approach was employed in this study due to the simplicity of preparation. Simple oxidative polymerization of the dopamine that creates the self-assembly monolayer seems to be an ideal choice. The QDs prepared by UV light irradiation synthesis were stabilized by using mercaptosuccinic acid. Formation of a complex of QD-antibody and QD-antibody-antigen was verified by using capillary electrophoresis with laser-induced fluorescence detection. QDs and antibody were connected together via an affinity peptide linker. LA-ICP-MS was employed as a proof-of-concept for detection method of two types of immunoassay: 1) antigen extracted from the sample by MIP and subsequently overlaid/immunoreacted by QD-labelled antibodies, 2) complex of antigen, antibody, and QD formed in the sample and subsequently extracted by MIP. The first approach provided higher sensitivity (MIP/NIP), however, the second demonstrated higher selectivity. A mixture of proteins with size in range 10-250 kDa was used as a model sample to demonstrate the capability of both approaches for detection of IgG in a complex sample.

Для цитирования: Vaneckova Tereza, Bezdekova Jaroslava, Tvrdonova Michaela, Vlcnovska Marcela, Novotna Veronika, Neuman Jan, Stossova Aneta, Kanicky Viktor, Adam Vojtech, Vaculovicova Marketa, Vaculovic Tomas. CdS quantum dots-based immunoassay combined with particle imprinted polymer technology and laser ablation ICP-MS as a versatile tool for protein detection.. Scientific reports. 2019. DOI: 10.1038/s41598-019-48290-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.