Safety and performance of a novel cerebral embolic protection device for transcatheter aortic valve implantation: the PROTEMBO C Trial.

Jagielak Dariusz, Targonski Radoslaw, Frerker Christian, Abdel-Wahab Mohamed, Wilde Johannes, Werner Nikos, Lauterbach Michael, Leick Juergen, Grygier Marek, Misterski Marcin, Erglis Andrejs, Narbute Inga, Witkowski Adam Ryszard, Adam Matti, Frank Derk, Gatto Fernando, Schmidt Tobias, Lansky Alexandra J

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Stroke remains a feared complication associated with transcatheter aortic valve implantation (TAVI). Embolic cerebral injury occurs in the majority of TAVI cases and can lead to cognitive dysfunction.

AIMS: The PROTEMBO C Trial evaluated the safety and performance of the ProtEmbo Cerebral Protection System in TAVI patients.

METHODS

Forty-one patients were enrolled in this single-arm study conducted at 8 European centres. The primary safety endpoint was the rate of VARC 2-defined major adverse cardiac and cerebrovascular events (MACCE) at 30 days; the primary performance endpoint was the composite rate of technical success versus performance goals (PG). Secondary endpoints included brain diffusion-weighted magnetic resonance imaging (DW-MRI), new lesion volume, and the rate of death or all strokes compared to historical data.

RESULTS

Thirty-seven of 41 enrolled patients underwent TAVI with the ProtEmbo device (intention-to-treat [ITT] population). Both primary endpoints were met. MACCE at 30 days was 8.1% (upper limit of the 95% confidence interval [CI]: 21.3% vs PG 25%; p=0.009), and technical success was 94.6% (lower limit of the 95% CI: 82.3% vs PG 75%; p=0.003). New DW-MRI lesion volumes with ProtEmbo were smaller than in historical data, and 87% of patients completing MRI follow-up had no single lesion >150 mm3. There was 1 stroke in a patient in whom the device was removed prematurely before TAVI completion.

CONCLUSIONS

The PROTEMBO C Trial met its primary safety and performance endpoints compared to prespecified historical PGs. Patients had smaller brain lesion volumes on DW-MRI compared to prior series and no larger single lesions. These results warrant further evaluation of the ProtEmbo in a larger randomised controlled trial (RCT).

Для цитирования: Jagielak Dariusz, Targonski Radoslaw, Frerker Christian, Abdel-Wahab Mohamed, Wilde Johannes, Werner Nikos, Lauterbach Michael, Leick Juergen, Grygier Marek, Misterski Marcin, Erglis Andrejs, Narbute Inga, Witkowski Adam Ryszard, Adam Matti, Frank Derk, Gatto Fernando, Schmidt Tobias, Lansky Alexandra J. Safety and performance of a novel cerebral embolic protection device for transcatheter aortic valve implantation: the PROTEMBO C Trial.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2022. DOI: 10.4244/eij-d-22-00238.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.