MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcct.2017.01.006

Медицинская библиотека · Journal of cardiovascular computed tomography · 2017

Sex differences in aortic root and vascular anatomy in patients undergoing transcatheter aortic valve implantation: A computed-tomographic study.

Hamdan Ashraf, Barbash Israel, Schwammenthal Ehud, Segev Amit, Kornowski Ran, Assali Abid, Shaviv Ella, Fefer Paul, Goitein Orly, Konen Eli, Guetta Victor

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Very little data exist on the impact of sex on aortic and arterial anatomy as relevant for transcatheter aortic valve implantation (TAVI).

OBJECTIVE

To investigate whether patients with severe aortic stenosis (AS) referred for TAVI display sex-specific differences in aortic root and ilio-femoral artery size.

METHODS

In 506 patients referred for pre-procedural CT evaluation before TAVI we performed a detailed assessment of aortic root anatomy: size of the annulus and the sinus of Valsalva (SoV), diameter of the sino-tubular junction (STJ), and distance of the coronary artery ostia to the aortic annulus plane; we also determined the dimensions of aorta, subclavian, and ilio-femoral arteries.

RESULTS

Women had significantly smaller aortic root dimensions (annulus mean diameter: 22.9 ± 2.2 mm vs. 25.7 ± 2.7 mm, SoV mean diameter: 31.8 ± 4.2 mm vs. 36.3 ± 3.8 mm, STJ mean diameter: 26.3 ± 3.4 mm vs. 29.8 ± 4.2 mm) and lower left and right coronary artery ostia take-off (12.3 ± 2.4 vs. 14.1 ± 2.9 mm; 14.8 ± 2.6 vs. 17.1 ± 3.2 mm, respectively) than men (P < 0.001 for all), even after adjustment for their smaller body surface area (BSA) and height. Dimensions of the ascending aorta, subclavian and ilio-femoral arteries were also significantly smaller in women, but not when adjusted for BSA.

CONCLUSIONS

Women with severe AS had smaller aortic root dimensions even after correcting for their smaller body size and height, reflecting a sex-specific difference. In contrast, sex-related differences in aortic, subclavian, and ilio-femoral dimensions were fully explained by the smaller BSA of women.

Для цитирования: Hamdan Ashraf, Barbash Israel, Schwammenthal Ehud, Segev Amit, Kornowski Ran, Assali Abid, Shaviv Ella, Fefer Paul, Goitein Orly, Konen Eli, Guetta Victor. Sex differences in aortic root and vascular anatomy in patients undergoing transcatheter aortic valve implantation: A computed-tomographic study.. Journal of cardiovascular computed tomography. 2017. DOI: 10.1016/j.jcct.2017.01.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.