MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2014.10.020

Медицинская библиотека · Biosensors & bioelectronics · 2014

A signal-off sandwich photoelectrochemical immunosensor using TiO2 coupled with CdS as the photoactive matrix and copper (II) ion as inhibitor.

Liu Yixin, Li Rongxia, Gao Picheng, Zhang Yong, Ma Hongmin, Yang Jiaojiao, Du Bin, Wei Qin

СтатьяПеревод в очереди

Аннотация

In this work, a novel sandwich photoelectrochemical (PEC) biosensor was developed based on a signal-off strategy using TiO2 coupled with CdS quantum dots (QDs) as the photoactive matrix and copper (II) ion (Cu(2+)) as inhibitor. TiO2/CdS modified indium tin oxide (ITO) electrode was employed for primary antibody (Ab1) immobilization and the subsequent sandwich-type antibody-antigen (Ab-Ag) affinity interactions. Flower-like copper oxide (CuO) was used as labels of secondary antibody (Ab2) and immobilized on the modified electrode via specific affinity interactions between Ab2 and Ag. Cu(2+) was released by dissolving CuO with HCl, and then reacted with CdS to form CuxS (x=1, 2), which would create new energy levels for electron-hole recombination and resulted in a decrease of the photocurrent. CuO, as the labels of Ab2, was first applied in PEC biosensor based on the signal-off strategy of the Cu(2+) for CdS. Greatly enhanced sensitivity was achieved through the coupling of CdS QDs with TiO2. Besides, the introduction of polythiophene (PT-Cl) on the surface of TiO2 made the PEC signal more stable. Under 405nm irradiation at 0.1V, the PEC biosensor for H-IgG determination exhibited a linear range from 0.1pgmL(-1) to 100ngmL(-1) with a low detection limit of 0.03pgmL(-1). The proposed biosensor showed high sensitivity, stability and selectivity, which opens up a new promising signal-off PEC platform for future bioassay.

Для цитирования: Liu Yixin, Li Rongxia, Gao Picheng, Zhang Yong, Ma Hongmin, Yang Jiaojiao, Du Bin, Wei Qin. A signal-off sandwich photoelectrochemical immunosensor using TiO2 coupled with CdS as the photoactive matrix and copper (II) ion as inhibitor.. Biosensors & bioelectronics. 2014. DOI: 10.1016/j.bios.2014.10.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.