MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4149/bll_2024_81

Медицинская библиотека · Bratislavske lekarske listy · 2024

Use of intraaortic balloon pump in cardiogenic shock patients.

Misun Peter, Sramko Marek, Kautzner Josef, Kettner Jiri, Zelizko Michal, Mares Jan, Bohm Allan, Kollarova Marta, Bezak Branislav, Pazdernik Michal

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

The relevance of the use of intra-aortic balloon pump (IABP) in cardiogenic shock (CS) has been discussed over the past years. The aim of this study is to describe a single-centre 10-year experience with IABP and analyse the risk factors for 30-day mortality.

METHODS

The data for this single-centre, observational, retrospective study were drawn from records dated from January 2012 to May 2022 pertaining to patients presenting with CS, treated with IABP and hospitalised at the Department of Acute Cardiology, Institute for Clinical and Experimental Medicine, Prague.

RESULTS

Among the patients included in the study, 87% patients presented with newly developed heart failure. The leading cause of CS was acute myocardial infarction accounting for 86% of cases. Hospital mortality was recorded at 39% and the 30-day mortality reached 43%. Upon multi-variable analysis, only the vasoactive inotropic score on day 5 emerged as a statistically significant predictor for 30-day mortality (p=0.0055). Cox regression analysis revealed that the presence of mechanical complications was the only variable identified as yielding a statistically significant impact on the 30-day survival (Log-rank p=0.014, HR 2.19, 95% CI: 1.15‒4.15). There was no statistically significant difference in the 30-day mortality across the SCAI classes.

CONCLUSION

The main cause of CS was a newly developed acute heart failure secondary to acute myocardial infarction. Despite the implementation of mechanical circulatory support, both in-hospital and 30-day mortality rates remained high. Increased vasoactive inotropic score and presence of mechanical complications were identified as significant predictors the 30-day survival (Tab. 6, Fig. 1, Ref. 36). Text in PDF www.elis.sk Keywords: cardiogenic shock, IABP, risk factors, mortality, Czech Republic, AMICS.

Для цитирования: Misun Peter, Sramko Marek, Kautzner Josef, Kettner Jiri, Zelizko Michal, Mares Jan, Bohm Allan, Kollarova Marta, Bezak Branislav, Pazdernik Michal. Use of intraaortic balloon pump in cardiogenic shock patients.. Bratislavske lekarske listy. 2024. DOI: 10.4149/bll_2024_81.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.