Critical care (London, England) · 2023
Angiotensin 1-7 in an experimental septic shock model.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Garcia Bruno, Su Fuhong, Manicone Francesca, Dewachter Laurence, Favory Raphaël, Khaldi Amina, Moiroux-Sahroui Alexander, Moreau Anthony, Herpain Antoine, Vincent Jean-Louis, Creteur Jacques, Taccone Fabio Silvio, Annoni Filippo
Аннотация
BACKGROUND: Alterations in the renin-angiotensin system have been implicated in the pathophysiology of septic shock. In particular, angiotensin 1-7 (Ang-(1-7)), an anti-inflammatory heptapeptide, has been hypothesized to have beneficial effects. The aim of the present study was to test the effects of Ang-(1-7) infusion on the development and severity of septic shock.
METHODS: This randomized, open-label, controlled study was performed in 14 anesthetized and mechanically ventilated sheep. Immediately after sepsis induction by bacterial peritonitis, animals received either Ang-(1-7) (n = 7) or placebo (n = 7) intravenously. Fluid resuscitation, antimicrobial therapy, and peritoneal lavage were initiated 4 h after sepsis induction. Norepinephrine administration was titrated to maintain mean arterial pressure (MAP) between 65 and 75 mmHg.
RESULTS: There were no differences in baseline characteristics between groups. Septic shock was prevented in 6 of the 7 animals in the Ang-(1-7) group at the end of the 24-h period. Fluid balance and MAP were similar in the two groups; however, MAP was achieved with a mean norepinephrine dose of 0.4 μg/kg/min in the Ang-(1-7) group compared to 4.3 μg/kg/min in the control group. Heart rate and cardiac output index were lower in the Ang (1-7) than in the control group, as were plasma interleukin-6 levels, and creatinine levels. Platelet count and PaO2/FiO2 ratio were higher in the Ang-(1-7) group. Mean arterial lactate at the end of the experiment was 1.6 mmol/L in the Ang-(1-7) group compared to 7.4 mmol/L in the control group.
CONCLUSIONS: In this experimental septic shock model, early Ang-(1-7) infusion prevented the development of septic shock, reduced norepinephrine requirements, limited interleukine-6 increase and prevented renal dysfunction.
METHODS: This randomized, open-label, controlled study was performed in 14 anesthetized and mechanically ventilated sheep. Immediately after sepsis induction by bacterial peritonitis, animals received either Ang-(1-7) (n = 7) or placebo (n = 7) intravenously. Fluid resuscitation, antimicrobial therapy, and peritoneal lavage were initiated 4 h after sepsis induction. Norepinephrine administration was titrated to maintain mean arterial pressure (MAP) between 65 and 75 mmHg.
RESULTS: There were no differences in baseline characteristics between groups. Septic shock was prevented in 6 of the 7 animals in the Ang-(1-7) group at the end of the 24-h period. Fluid balance and MAP were similar in the two groups; however, MAP was achieved with a mean norepinephrine dose of 0.4 μg/kg/min in the Ang-(1-7) group compared to 4.3 μg/kg/min in the control group. Heart rate and cardiac output index were lower in the Ang (1-7) than in the control group, as were plasma interleukin-6 levels, and creatinine levels. Platelet count and PaO2/FiO2 ratio were higher in the Ang-(1-7) group. Mean arterial lactate at the end of the experiment was 1.6 mmol/L in the Ang-(1-7) group compared to 7.4 mmol/L in the control group.
CONCLUSIONS: In this experimental septic shock model, early Ang-(1-7) infusion prevented the development of septic shock, reduced norepinephrine requirements, limited interleukine-6 increase and prevented renal dysfunction.