European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2017
Long-term results following emergency stent graft repair for traumatic rupture of the aortic isthmus.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Martin Cecile, Thony Frederic, Rodiere Mathieu, Bouzat Pierre, Lavagne Pierre, Durand Michel, Chavanon Olivier
Аннотация
OBJECTIVES: Endovascular repair of traumatic injury of the aortic isthmus is a safe technique that has shown good short-term results. However, the future of these stent grafts remains unexamined, especially in relation to young patients.
METHODS: Between January 2000 and December 2014, 60 patients were treated with endovascular aortic stent graft for injury of the aortic isthmus. Follow-up was done by computed tomography scans with intravenous contrast or magnetic resonance imaging associated with a chest X-ray in order to control the stent graft.
RESULTS: In total, 48 men (80%) were included; the average age was 43 ± 17 years [17; 79]. The median time between the accident and endovascular repair was 6 h. Endovascular repair was successful in all cases with no cerebrovascular or paraplegia after treatment. Seventeen patients (27.3%) received a total coverage of the left subclavian artery; one of them received a subclavian carotid bypass. Mean follow-up was 5 years with a maximum of 14 years. There was no repeat surgery related to the aorta during follow-up. No stent graft failure, neurological or ischaemic event related to the stent graft was noted. One patient had a type 1 endoleak without any reintervention. The survival rate was 86.5% in 1 year, 81.6% in 5 years and 75.3% in 10 years.
CONCLUSIONS: Treatment of injuries of the aortic isthmus with stent graft seems to be a safe long-term technique; we did not notice any event related to the stent graft during the follow-up.
METHODS: Between January 2000 and December 2014, 60 patients were treated with endovascular aortic stent graft for injury of the aortic isthmus. Follow-up was done by computed tomography scans with intravenous contrast or magnetic resonance imaging associated with a chest X-ray in order to control the stent graft.
RESULTS: In total, 48 men (80%) were included; the average age was 43 ± 17 years [17; 79]. The median time between the accident and endovascular repair was 6 h. Endovascular repair was successful in all cases with no cerebrovascular or paraplegia after treatment. Seventeen patients (27.3%) received a total coverage of the left subclavian artery; one of them received a subclavian carotid bypass. Mean follow-up was 5 years with a maximum of 14 years. There was no repeat surgery related to the aorta during follow-up. No stent graft failure, neurological or ischaemic event related to the stent graft was noted. One patient had a type 1 endoleak without any reintervention. The survival rate was 86.5% in 1 year, 81.6% in 5 years and 75.3% in 10 years.
CONCLUSIONS: Treatment of injuries of the aortic isthmus with stent graft seems to be a safe long-term technique; we did not notice any event related to the stent graft during the follow-up.
Предметные рубрики MeSH
AdolescentAdultAgedAorta, ThoracicAortic RuptureBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationEmergenciesEndovascular ProceduresFemaleFollow-Up StudiesHumansKaplan-Meier EstimateMagnetic Resonance ImagingMaleMiddle AgedRetrospective StudiesStentsTomography, X-Ray ComputedTreatment OutcomeWounds, NonpenetratingYoung Adult