MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/a-2749-6487

Медицинская библиотека · Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2025

Percutaneous Fracture Reduction of Cadaveric Feline Tibiae (Gap Model) Using Computed Tomography, Computer Design Software, and Three-Dimensional-Printed Fixateur Externe Type 1.

Marten Felix, Kramer Sabine, Huels Nikolaus

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study aimed to evaluate percutaneous reduction of feline tibial fractures (gap model) using a three-dimensional-printed external skeletal fixator (jig) and assess the contralateral tibia as a template for virtual planning.

STUDY

DESIGN

Postmortem computed tomography (CT) was performed on 11 skeletally mature feline specimens. A mid-shaft tibial fracture gap model was created, followed by the placement of two lead-marked K-wires per fragment. The DICOMS images of repeated CT scans were imported into the virtual planning software to design a specimen-specific jig using the contralateral side as a template. The jig housed the leads and acted as a connecting bar to facilitate fracture reduction. Post-procedure radiography and CT were performed to evaluate fracture reduction.

RESULTS

A total of 22 tibiae of 11 cats were reduced using a jig. There was an average difference of <1 mm in terms of tibial length and <5 degrees in joint angulations and in terms of rotation when comparing the post-procedure tibia with the initial CT/radiograph (p < 0.05). The alignment was considered anatomical in 16 of 21 limbs and acceptable in 5 of 21 limbs. Pin loosening occurred in one case during the jig process.

CONCLUSION

Temporary fracture reduction using the three-dimensional-printed jig was feasible and accurate in 21 of the 22 procedures. When using the contralateral tibia as a template, an asymmetry of up to 6% in terms of joint angulations should be considered.

Для цитирования: Marten Felix, Kramer Sabine, Huels Nikolaus. Percutaneous Fracture Reduction of Cadaveric Feline Tibiae (Gap Model) Using Computed Tomography, Computer Design Software, and Three-Dimensional-Printed Fixateur Externe Type 1.. Veterinary and comparative orthopaedics and traumatology : V.C.O.T. 2025. DOI: 10.1055/a-2749-6487.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.