Comparison of refractive parameters provided by a new open field aberrometer and the subjective refraction.

СтатьяСравнительное исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Martinez-Abad Antonio, Yebana-Rubio Pilar, Plaza-Puche Ana Belén, Rodríguez Alejandra Eliana, José-Martínez Marina, Piñero David P, Alió Jorge L, Cantó-Cerdán Mario

Аннотация

PURPOSE: To compare and evaluate the agreement between refractive measurements obtained by the new open-field OFA-Osiris (CSO®) aberrometer and the subjective refraction. METHODS: Observational, prospective, cross-sectional study involving healthy eyes. Subjects underwent a subjective refraction and ocular aberrometry using the OFA-Osiris device. Sphere, cylinder, and axis values obtained from both methods were converted to polar notation using M, J0 and J45 vectors. Refractive data from ocular aberrometry were extracted at 4 and 5 mm pupil diameters. The Wilcoxon sum-rank test was used to compare the methods, and Bland-Altman plots were used for the agreement analysis. RESULTS: 183 eyes from 183 subjects (mean age: 24.9 ± 5.2 years) were included. No significant differences were found between the subjective and the objective refractive obtained with the OFA-Osiris aberrometer considering a pupil diameter of 5 mm for astigmatic parameters (J0 0.01 ± 0.19 D vs. 0.02 ± 0.26 D, J45 0.03 ± 0.21 D vs. 0.01 ± 0.24, p > 0.05) but a significant difference were observed in terms of spherical equivalent (M -1.42 ± 2.06 D vs. -1.50 ± 2.17 D, p: 0.001) When considering a pupil diameter of 4 mm for the objective refraction measurement, no significant differences were observed in any refractive parameter (M -1.42 ± 2.06 D vs. 1.42 ± 2.25, J0 0.01 ± 0.19 D vs. 0.01 ± 0.265 D, J45 0.03 ± 0.21 D vs. 0.01 ± 0.26, p > 0.05). Bland-Altman plots revealed 95% confidence intervals higher than 0.50 D. CONCLUSION: Aberrometric refraction provided by the new open-field aberrometer, OFA-Osiris, showed general good agreement with subjective refraction – particularly for a pupil diameter of 4 mm – but not being totally interchangeable by the presence of some unacceptable cases and recommending the subjective refraction as gold standard for refractive evaluation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты