Heart rhythm · 2022

High-resolution mapping of reentrant atrial tachycardias: Relevance of low bipolar voltage.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ramirez F Daniel, Meo Marianna, Dallet Corentin, Krisai Philipp, Vlachos Konstantinos, Frontera Antonio, Takigawa Masateru, Nakatani Yosuke, Nakashima Takashi, André Clémentine, Kamakura Tsukasa, Takagi Takamitsu, Carapezzi Aline, Tixier Romain, Chauvel Rémi, Cheniti Ghassen, Duchateau Josselin, Pambrun Thomas, Sacher Frédéric, Hocini Mélèze, Haïssaguerre Michel, Jaïs Pierre, Dubois Rémi, Derval Nicolas

Аннотация

BACKGROUND: Bipolar voltage is widely used to characterize the atrial substrate but has been poorly validated, particularly during clinical tachycardias.

OBJECTIVE: The purpose of this study was to evaluate the diagnostic performance of voltage thresholds for identifying regions of slow conduction during reentrant atrial tachycardias (ATs).

METHODS: Thirty bipolar voltage and activation maps created during reentrant ATs were analyzed to (1) examine the relationship between voltage amplitude and conduction velocity (CV), (2) measure the diagnostic ability of voltage thresholds to predict CV, and (3) identify determinants of AT circuit dimensions. Voltage amplitude was categorized as "normal" (>0.50 mV), "abnormal" (0.05-0.50 mV), or "scar" (<0.05 mV); slow conduction was defined as <30 cm/s.

RESULTS: A total of 266,457 corresponding voltage and CV data points were included for analysis. Voltage and CV were moderately correlated (r = 0.407; P < .001). Bipolar voltage predicted regions of slow conduction with an area under the receiver operating characteristic curve of 0.733 (95% confidence interval 0.731-0.735). A threshold of 0.50 mV had 91% sensitivity and 35% specificity for identifying slow conduction, whereas 0.05 mV had 36% sensitivity and 87% specificity, with an optimal voltage threshold of 0.15 mV. Analyses restricted to the AT circuits identified weaker associations between voltage and CV and an optimal voltage threshold of 0.25 mV.

CONCLUSION: Widely used bipolar voltage amplitude thresholds to define "abnormal" and "scar" tissue in the atria are, respectively, sensitive and specific for identifying regions of slow conduction during reentrant ATs. However, overall, the association of voltage with CV is modest. No clinical predictors of AT circuit dimensions were identified.