Archives of pathology & laboratory medicine · 2019
Measurements in First-Trimester Abortion Products: A Pathologic Study.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Nogueira Rosete, Sousa Sara, Braga Ana Cristina, Azevedo Ana, Pereira Nuno, Carmo Olímpia, Tavares Maria Purificação, Pinto Jorge Correia
Аннотация
CONTEXT.—: Related to the advances in prenatal diagnosis and the emergence of medically challenging situations, there has been an increased interest in conducting a pathologic study of first-trimester abortion products.
OBJECTIVE.—: To evaluate measurements across a large group of first-trimester spontaneous abortion specimens. Potential goals include a validation of prenatal embryo and gestational-sac measurements as a function of gestational age (GA).
DESIGN.—: A retrospective case study of first-trimester spontaneous abortions between June 2015 and April 2017 in Centro de Genética Clínica Embryo-Fetal Pathology Laboratory, Porto, Portugal. Considering the inclusion criteria, 585 complete gestational sacs, 182 embryos, and 116 umbilical cords were selected. We recorded the weight of the gestational sacs and embryos and measurements of gestational sacs, umbilical cords, and embryo crown-rump length. Models were computed using regression techniques.
RESULTS.—: Gestational-sac diameter percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval the diameter increased an average of 3 mm. Umbilical cord length percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval, the length increased an average of 1.35 mm. Embryo crown-rump length estimated mean ± SD values were GA 6 weeks, 5.3 ± 2.3 mm; GA 7 weeks, 9.4 ± 4.8 mm; GA 8 weeks, 13.7 ± 8.2 mm; GA 9 weeks, 20.8 ± 9.1 mm; GA 10 weeks, 22.6 ± 13.4 mm; GA 11 weeks, 29.4 ± 12.9 mm; and GA 12 weeks, 52 mm.
CONCLUSIONS.—: Pathologic measurements obtained should be compared to expected measurements and correlated with ultrasound findings, clinical information, and microscopic findings. Deviations from expected values could lead to an understanding of early pregnancy loss.
OBJECTIVE.—: To evaluate measurements across a large group of first-trimester spontaneous abortion specimens. Potential goals include a validation of prenatal embryo and gestational-sac measurements as a function of gestational age (GA).
DESIGN.—: A retrospective case study of first-trimester spontaneous abortions between June 2015 and April 2017 in Centro de Genética Clínica Embryo-Fetal Pathology Laboratory, Porto, Portugal. Considering the inclusion criteria, 585 complete gestational sacs, 182 embryos, and 116 umbilical cords were selected. We recorded the weight of the gestational sacs and embryos and measurements of gestational sacs, umbilical cords, and embryo crown-rump length. Models were computed using regression techniques.
RESULTS.—: Gestational-sac diameter percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval the diameter increased an average of 3 mm. Umbilical cord length percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval, the length increased an average of 1.35 mm. Embryo crown-rump length estimated mean ± SD values were GA 6 weeks, 5.3 ± 2.3 mm; GA 7 weeks, 9.4 ± 4.8 mm; GA 8 weeks, 13.7 ± 8.2 mm; GA 9 weeks, 20.8 ± 9.1 mm; GA 10 weeks, 22.6 ± 13.4 mm; GA 11 weeks, 29.4 ± 12.9 mm; and GA 12 weeks, 52 mm.
CONCLUSIONS.—: Pathologic measurements obtained should be compared to expected measurements and correlated with ultrasound findings, clinical information, and microscopic findings. Deviations from expected values could lead to an understanding of early pregnancy loss.