Regional air trapping in acute exacerbation of obstructive lung diseases measured with electrical impedance tomography: a feasibility study.

Zhao Zhanqi, Chang Mei-Yun, Frerichs Inéz, Zhang Jia-Hao, Chang Hou-Tai, Gow Chien-Hung, Möller Knut

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Since bronchial abnormalities often exhibit spatial non-uniformity which may be not correctly assessed by conventional global lung function measures, regional information may help to characterize the disease progress. We hypothesized that regional air trapping during mechanical ventilation could be characterized by regional end-expiratory flow (EEF) derived from electrical impedance tomography (EIT).

METHODS

Twenty-five patients suffering from chronic obstructive pulmonary disease (COPD grade 3 or 4) or severe asthma with acute exacerbation were examined prospectively. Patients were ventilated under assist-control mode. EIT measurements were conducted before and one hour after inhaled combined corticosteroid and long-acting β2 agonist, on two consecutive days. Regional EEF was calculated as derivative of relative impedance for every image pixel in the lung regions. The results were normalized to global flow values measured by the ventilator.

RESULTS

Regional and global EEF were highly correlated (P<0.00001) and regional effects of medication and disease progression were visible in the regional EEF maps. The sums of regional EEF in lung regions were 3.8 [2.0, 5.1] and 3.6 [1.9, 4.5] L/min in COPD patients before and after medication (median [lower, upper quartiles]; P=0.37). The corresponding values in asthma patients were 3.0 [2.5, 4.2] and 2.2 [1.7, 3.2] L/min (P<0.05). Histograms of regional EEF showed high spatial heterogeneity of EEF before medication. After one day of treatment, the histograms exhibited less heterogeneous and a decrease in EEF level.

CONCLUSIONS

Regional EEF characterizes air trapping and intrinsic PEEP, which could provide diagnostic information for monitoring the disease progress during treatment.

Для цитирования: Zhao Zhanqi, Chang Mei-Yun, Frerichs Inéz, Zhang Jia-Hao, Chang Hou-Tai, Gow Chien-Hung, Möller Knut. Regional air trapping in acute exacerbation of obstructive lung diseases measured with electrical impedance tomography: a feasibility study.. Minerva anestesiologica. 2019. DOI: 10.23736/s0375-9393.19.13732-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.