Catheter Ablation of Ventricular Tachycardia in Patients With MitraClip Device: Preliminary Findings.

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Haegeli Laurent M, D'Angelo Giuseppe, Trevisi Nicola, Stella Stefano, Breitenstein Alexander, Duru Firat, Brunckhorst Corinna, Della Bella Paolo

Аннотация

INTRODUCTION: Patients with mitral regurgitation are increasingly treated by percutaneous implantation of a MitraClip device (Abbott Park, IL, USA). We investigate the feasibility and safety of the transmitral catheter route for catheter ablation of ventricular tachycardia (VT) in these patients.

METHODS: The mitral valve with the MitraClip in situ was crossed under transesophageal 3-dimensional echocardiographic and fluoroscopic guidance using a steerable sheath for ablation of the left ventricle.

RESULTS: Five patients (all males, median age 74.0 ± 16.0 years) who had previously a MitraClip implanted were referred for catheter ablation of VT. The left ventricular ejection fraction was 29.0% ± 24.0%. One patient had both an atrial septal defect and a left atrial appendage occluder device in addition to a MitraClip. The duration between MitraClip implantation and ablation was 1019.0 ± 783.0 days. After transseptal puncture, ablation catheter was successfully steered through the mitral valve with the use of fluoroscopy. A complete high-density map of the substrate in sinus rhythm could be obtained in all patients using multipolar mapping catheters. In 1 patient, mapping was carried out using a mini-basket catheter. Procedural endpoints, noninducibility of all VTs, and abolition of all late potentials were achieved in all patients. Procedure time was 255.0 ± 52.5 minute, fluoroscopy time was 23.0 ± 7.3, and the radiation dose was 61.0 ± 37.5 Gycm2 . No mitral insufficiency or worsening of regurgitation was documented after the procedure.

CONCLUSIONS: This is the first report demonstrating the feasibility and safety of VT ablation in patients with a MitraClip device using the anterograde transmitral catheter route.