MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2340/16501977-2173

Медицинская библиотека · Journal of rehabilitation medicine · 2017

Effect on body composition and bone mineral density of walking with a robotic exoskeleton in adults with chronic spinal cord injury.

Karelis Antony D, Carvalho Lívia Pinheiro, Castillo Manuel Jose, Gagnon Dany H, Aubertin-Leheudre Mylène

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To examine the effect on body composition and bone mineral density of locomotor training using a robotic exoskeleton in individuals with spinal cord injury.

STUDY

DESIGN

Interventional study.

SUBJECTS/

METHODS

Five adults with a non-progressive traumatic complete sensorimotor spinal cord injury who were using a wheelchair as a primary mode of mobility. Participants performed a personalized 6-week progressive locomotor training programme using a robotic exoskeleton 3 times/week for up to 60 min. Body composition measures were determined using dual energy X-ray absorptiometry and peripheral quantitative computed tomography.

RESULTS

A significant increase in leg and appendicular lean body mass and a decrease in total, leg and appendicular fat mass was observed after the intervention. Furthermore, the calf muscle cross-sectional area increased significantly after the intervention. Finally, although not statistically significant, there was an increase of 14.5% in bone mineral density of the tibia, which may be clinically significant. A decrease of > 5 % was also noted for subcutaneous adipose tissue and intramuscular adipose tissue.

CONCLUSION

Locomotor training using a robotic exoskeleton appears to be associated with improvements in body composition and, potentially, bone health.

Для цитирования: Karelis Antony D, Carvalho Lívia Pinheiro, Castillo Manuel Jose, Gagnon Dany H, Aubertin-Leheudre Mylène. Effect on body composition and bone mineral density of walking with a robotic exoskeleton in adults with chronic spinal cord injury.. Journal of rehabilitation medicine. 2017. DOI: 10.2340/16501977-2173.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.