MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcha.2016.05.007

Медицинская библиотека · International journal of cardiology. Heart & vasculature · 2016

Accuracy of quantitative echocardiographic measures of right ventricular function as compared to cardiovascular magnetic resonance.

Hamilton-Craig Christian R, Stedman Kathy, Maxwell Ryan, Anderson Bonita, Stanton Tony, Chan Jonathan, Yamada Akira, Scalia Gregory M, Burstow Darryl J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Many echocardiographic parameters have been proposed to evaluate right ventricular (RV) systolic function. We comprehensively assessed a wide range of quantitative echocardiographic parameters in a single cohort compared with same-day cardiovascular magnetic resonance (CMR).

METHODS AND

RESULTS

92 subjects were examined prospectively: Group 1 consisted of 46 healthy controls (21 males, 33.4 ± 11.4 years), Group 2 consisted of 46 patients (20 males, 38.5 ± 18.9 years) undergoing RV functional assessment by CMR (1.5 T). Echocardiography was performed on the same day as CMR; fractional area change (RVFAC), myocardial performance index via spectral Doppler (RVMPI), RVMPI via Doppler tissue imaging (RVMPI-DTI), peak systolic myocardial velocity by DTI (RVSm), tricuspid annular plane systolic excursion (TAPSE), speckle tracking strain, and three dimensional right ventricular ejection fraction (3DE-RV). Linear regression, Bland-Altman and receiver-operator-characteristic (ROC) analyses were performed. At ROC analysis, the most predictive echocardiographic methods were; RVFAC (AUC = 0.892), RVMPI (AUC 0.785), TAPSE (AUC 0.849) and 3DE-RV (AUC 0.909). 3DE-RV appeared the most accurate compared to CMR, although underestimated true RV volumes.

CONCLUSION

As compared to CMR; 3DE-RV, RVFAC, TAPSE and RVMPI were the most reliable predictors of RV function. These parameters can be recommended for clinical use.

Для цитирования: Hamilton-Craig Christian R, Stedman Kathy, Maxwell Ryan, Anderson Bonita, Stanton Tony, Chan Jonathan, Yamada Akira, Scalia Gregory M, Burstow Darryl J. Accuracy of quantitative echocardiographic measures of right ventricular function as compared to cardiovascular magnetic resonance.. International journal of cardiology. Heart & vasculature. 2016. DOI: 10.1016/j.ijcha.2016.05.007.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.