Electromagnetic-guided placement of nasoduodenal feeding tubes versus endoscopic placement: a randomized, multicenter trial.

Kappelle Wouter F W, Walter Daisy, Stadhouders Paul H, Jebbink Hendrik J A, Vleggaar Frank P, van der Schaar Peter J, Kappelle Jan Willem, van der Tweel Ingeborg, Van den Broek Medard F M, Wessels Frank J, Siersema Peter D, Monkelbaan Jan F

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Electromagnetic-guided placement (EMP) of a nasoduodenal feeding tube by trained nurses is an attractive alternative to EGD-guided placement (EGDP). We aimed to compare EMP and EGDP in outpatients, ward patients, and critically ill patients with normal upper GI anatomy.

METHODS

In 3 centers with no prior experience in EMP, patients were randomized to placement of a single-lumen nasoduodenal feeding tube either with EGDP or EMP. The primary endpoint was post-pyloric position of the tube on abdominal radiography. Patients were followed for 10 days to assess patency and adverse events. The analyses were performed according to the intention-to-treat principle.

RESULTS

In total, 160 patients were randomized to EGDP (N = 76) or EMP (N = 84). Three patients withdrew informed consent, and no abdominal radiography was performed in 2 patients. Thus, 155 patients (59 intensive care unit, 38%) were included in the analyses. Rates of post-pyloric tube position between EGDP and EMP were comparable (79% vs 82%, odds ratio 1.16; 90% confidence interval, 0.58-2.38; P = .72). Adverse events were observed in 4 patients after EMP (hypoxia, GI blood loss, atrial fibrillation, abdominal pain) and in 4 after EGDP (epistaxis N = 2, GI blood loss, hypoxia). Costs of tube placements were lower for EMP compared with EGDP: $519.09 versus $622.49, respectively (P = .04).

CONCLUSIONS

Success rates and safety of EMP and EGDP in patients with normal upper GI anatomy were comparable. Lower costs and potential logistic advantages may drive centers to adopt EMP as their new standard of care. (Clinical trial registration number: NTR4286.).

Для цитирования: Kappelle Wouter F W, Walter Daisy, Stadhouders Paul H, Jebbink Hendrik J A, Vleggaar Frank P, van der Schaar Peter J, Kappelle Jan Willem, van der Tweel Ingeborg, Van den Broek Medard F M, Wessels Frank J, Siersema Peter D, Monkelbaan Jan F. Electromagnetic-guided placement of nasoduodenal feeding tubes versus endoscopic placement: a randomized, multicenter trial.. Gastrointestinal endoscopy. 2017. DOI: 10.1016/j.gie.2017.05.033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.