Аннотация

OBJECTIVE

To estimate the risk of bloodstream infection associated with catheter dwell time in infants.

DESIGN

Retrospective study.

SETTING

Duke University Medical Center neonatal intensive care unit, an academic, level 3 nursery in Durham, North Carolina.

METHODS

A case of catheter-associated bloodstream infection was defined as one that occurred in an infant whose culture-positive blood sample was collected more than 24 hours after catheter insertion or within 72 hours after catheter removal. We used multivariable logistic regression to control for the catheter's position and dwell time as well as the infant's sex, gestational age, age at time of catheter insertion, birth weight, and weight at time of catheter insertion.

RESULTS

We identified 135 cases of catheter-associated bloodstream infection. The mean catheter dwell time was 12.2 days (range, 0-113 days), and the mean time to bloodstream infection was 10.8 days (range, 1-57 days). An increase in catheter dwell time was associated with a lower risk of bloodstream infection (odds ratio, 0.975 [95% confidence interval, 0.954-0.996]; P = .02).

CONCLUSION

No increased risk of catheter-associated bloodstream infection was observed with increased catheter dwell time. This may have been due to the infant's improved nutrition, decreased need for other invasive devices, and maturing skin and immune system as catheter dwell time increased.

Для цитирования: Smith P Brian, Benjamin Daniel K, Cotten C Michael, Schultz Eric, Guo Rose, Nowell Lisa, Smithwick Mary Laura, Thornburg Courtney D. Is an increased dwell time of a peripherally inserted catheter associated with an increased risk of bloodstream infection in infants?. Infection control and hospital epidemiology. 2008. DOI: 10.1086/589905.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.