m+Medelevator.RU
← Поиск публикаций
Japanese journal of radiology · 2009

Detection of masses and calcifications by soft-copy reading: comparison of two postprocessing algorithms for full-field digital mammography.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Uematsu Takayoshi

Аннотация

PURPOSE: The purpose of this study was to determine the effects of a commercially available postprocessing algorithm on the detection of masses and microcalcifications of breast cancer by soft-copy reading.

MATERIALS AND METHODS: The study included 64 digital mammograms with 16 histologically proven abnormal findings (eight masses and eight microcalcifications) and 48 normal breasts. Two image-processing algorithms were applied to the digital images, which were acquired using General Electric units. The commercially available advanced and standard postprocessed digital mammograms were evaluated in a localization receiver operating characteristic (ROC) curve experiment involving seven mammography radiographers.

RESULTS: The mean area under the ROC curve was 0.921 +/- 0.022 for the commercially available advanced postprocessed digital mammograms session and 0.904 +/- 0.026 for the standard postprocessed digital mammograms session (P = 0.1953). Observer agreement among the readers was better for the advanced postprocessed digital mammograms than for the standard postprocessed digital mammograms.

CONCLUSION: During soft-copy reading, the interpretation accuracy might be influenced by the postprocessing algorithm.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты