High-Frequency Repetitive Transcranial Magnetic Stimulation at 20 Hz: A Case Series Evaluating Efficacy in Treatment-Resistant Migraine After 10 Hz Repetitive Transcranial Magnetic Stimulation Failure.

СтатьяКлинический случайНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Khairkar Praveen, Khoiwal Rajesh, Bamal Ishu, Khivsara Archish, Gupta Navendra Kumar, Pateriya Anurag, Modi Rohan, Khaikar Rajesh, Peerzada Murtaza

Аннотация

BACKGROUND: High-frequency transcranial magnetic stimulation (TMS) interventions were approved for migraine headache by the US Food and Drug Administration since 2013; however, it is unclear if 10 Hz frequency repetitive TMS (rTMS) patient relapses, should frequency of TMS be enhanced to 20 Hz protocol? This case series addresses the effectiveness of 20 Hz frequency rTMS in treatment-refractory migraine patients.

CASE REPORT: Five voluntary treatment-refractory migraine patients, referred from Medicine, Neurology, and Neurosurgery departments with mean duration of 11.8 years of migraine, not responding to any medications and failed to respond to 10 Hz frequency standard international guidelines, were subjected to 20 Hz, 5 sessions in the first week followed by weekly sessions for additional 4 weeks.

CONCLUSIONS: Compared to initial 10 Hz treatment, 20 Hz rTMS significantly reduced both frequency and severity of migraine. Over a follow-up period of 3-6 months, patients exhibited lasting improvements, indicating that 20 Hz rTMS is an effective neuromodulation intervention for individuals with refractory migraines.