DOI 10.1007/s00595-025-03033-x
Impedance-based detection of cervical lymph-node involvement in thyroid cancer patients: a human model study.
Аннотация
PURPOSE: Current diagnostic modalities for differentiating between benign and malignant cervical lymph nodes in patients with thyroid cancer are imprecise and time-consuming. The real-time intraoperative detection of malignancy in suspicious lesions could improve the medical management of these patients. This human study was undertaken to evaluate a precise, newly developed Electrical Lymph-Node Scanning (ELS) system to facilitate the effective treatment of cervical LNs in thyroid cancer patients.
METHODS
Using the ELS, we examined a collective 109 radiologically suspicious lymph nodes from 36 patients after dissection and compared the ELS results with the histopathological findings.
RESULTS
A total of 27 involved lymph nodes were correctly diagnosed, while 75 reactive or free lymph nodes were correctly identified as uninvolved lymph nodes by ELS (as 3 false negatives and 4 false positives) with total sensitivity and specificity of 90% and 94.9%, respectively. The corresponding negative and positive predictive values were 87.1% and 96.2%, respectively.
CONCLUSIONS
Results from this clinical study demonstrate the value of the ELS as a surgical assist adjunct for differentiating equivocal lesions during neck dissection surgery for patients with different types of thyroid cancer.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.