MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/03091902.2016.1148791

Медицинская библиотека · Journal of medical engineering & technology · 2016

RemLogic plug-in enables clinical application of apnea-hypopnea index adjusted for severity of individual obstruction events.

Leppänen Timo, Särkkä Mikko, Kulkas Antti, Muraja-Murro Anu, Kupari Salla, Anttonen Meri, Tiihonen Pekka, Mervaala Esa, Töyräs Juha

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Obstructive sleep apnea (OSA) is diagnosed based on obstruction event incidence, albeit individual obstruction event severity is connected to increased mortality rate. Adjusted-AHI parameter, incorporating number and severity of obstruction events, has shown good potential, but is calculated using custom-made MATLAB(®) functions. To allow its clinical use, this study introduces the RemLogic™ plug-in. It is tested comparing adjusted-AHI values calculated with the plug-in and MATLAB(®) with a hundred patients. Furthermore, retrospective follow-up (mean ± SD = 194.1 ± 54.0 months) of 1128 working-age men was conducted to evaluate potential of adjusted-AHI to enhance diagnostic of OSA. Adjusted-AHI values were strongly correlated (r = 1.000, p < 0.001) and their average difference (mean ± SD) was minimal (0.08 ± 0.19%). Using adjusted-AHI to define OSA severity resulted in a higher hazard ratio of mortality in the severe OSA group and, for the first time, adjusted-AHI was found to explain independently the overall mortality and non-fatal cardiovascular events. Importantly, the present plug-in enables clinical use of adjusted-AHI, enhancing assessment of OSA severity.

Для цитирования: Leppänen Timo, Särkkä Mikko, Kulkas Antti, Muraja-Murro Anu, Kupari Salla, Anttonen Meri, Tiihonen Pekka, Mervaala Esa, Töyräs Juha. RemLogic plug-in enables clinical application of apnea-hypopnea index adjusted for severity of individual obstruction events.. Journal of medical engineering & technology. 2016. DOI: 10.3109/03091902.2016.1148791.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.