The American journal of cardiology · 1976

Regional myocardial blood flow during hyperemia induced by contrast agent in patients with coronary artery disease.

СтатьяПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Holman B L, Cohn P F, Adams D F, See J R, Roberts B H, Idoine J, Gorlin R

Аннотация

Regional myocardial specific blood flow (regional specific flow) was measured at rest and during contrast hyperemia after the intracoronary injection of xenon-133. The changes in regional specific flow were transient, resulting in some compromise in one of the underlying restraints of the inert gas washout method, namely, the presence of a steady state. Therefore, to determine the clinical utility of this technique, regional specific flow values obtained with this method were correlated with the presence and severity of coronary artery disease as assessed from the coronary arteriogram and left ventriculogram. Regional specific flow during contrast hyperemia was 186+/- 11 (mean +/- 1 standard error of the mean) ml/min per 100 g in control patients and 115+/-5 in patients with coronary artery disease. There was an inverse relation between regional specific flow during contrast hyperemia and the percent coronary stenosis when the stenosis was 40 percent or greater (r = 0.70, P less than 0.001). Regional specific flow was significantly less in patients with asynergy (77 +/- 10 ml/min per 100 g) than in patients with normal ventricular function (105 +/- 5) distal to coronary stenoses of greater than 75 percent. Thus regional specific flow measured during contrast hyperemia using the xenon washout technique and the Anger camera differentiated patients with normal coronary arteriograms from those with coronary artery disease. With this technique, good correlation was shown between regional specific flow and the percent coronary stenosis and presence of ventricular wall abnormalities. The information obtained with this method may provide prognostic information concerning suitability for surgical intervention.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты