Occlutech percutaneous patent foramen ovale closure: Safety and efficacy registry (OPPOSE).

Hildick-Smith David, Williams Timothy, MacCarthy Philip, Melikian Narbeh, Monaghan Mark, Spence Mark, MacDonald Simon T, Duke Abdul, Kovac Jan, McGregor Andrew, Hilling-Smith Roland, Gomes Arionilson, Thomson Catherine, Mullen Michael, Morrison Lindsay

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

INTRODUCTION

Safety and efficacy data on patent foramen ovale (PFO) closure with the Occlutech Figulla Flex II device are lacking. We undertook a fully monitored prospective Registry on PFO closure using this device.

METHODS

100 patients undergoing PFO closure were enrolled into the OPPOSE Registry at 6 UK centres. The primary endpoint was PFO closure (grade 0 or 1 shunt) at 6-month BCTTE assessed by Corelab. Secondary endpoints included implantation success, complications, and atrial fibrillation during follow-up.

RESULTS

100 patients aged 43.8±11.5years, 53% male, were recruited. Indications for PFO closure included stroke (56%), TIA (29%) systemic embolism (4%) and MI (3%). Closure was undertaken under GA (44%) or LA (56%), with TOE (45%), ICE (31%), no imaging (20%) or TTE (3%). Balloon sizing was used in 98% of cases and showed a tunnel length of 7.3±3.6mm, primum-secundum separation of 7.0±2.9mm and basal inlet width of 8.5±3.5mm. Implantation was successful in all cases using 18mm (9%), 25mm (80%), 30mm (10%) and 35mm (1%) devices. 5 patients were lost to follow-up. 92 patients underwent six-month BCTTE. The primary endpoint of PFO closure (grade 0 or 1 shunt) at six months was 79.3%. One patient developed major bleeding (BARC 3b), one patient required vascular surgery, and in one patient device embolization was noted at six months and a larger device implanted. There was one case of new atrial fibrillation.

CONCLUSIONS

This first prospective monitored data for the Occlutech Figulla Flex II device demonstrates good safety and efficacy data at implant and six-month follow-up.

Для цитирования: Hildick-Smith David, Williams Timothy, MacCarthy Philip, Melikian Narbeh, Monaghan Mark, Spence Mark, MacDonald Simon T, Duke Abdul, Kovac Jan, McGregor Andrew, Hilling-Smith Roland, Gomes Arionilson, Thomson Catherine, Mullen Michael, Morrison Lindsay. Occlutech percutaneous patent foramen ovale closure: Safety and efficacy registry (OPPOSE).. International journal of cardiology. 2017. DOI: 10.1016/j.ijcard.2017.07.058.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.