Pacing and clinical electrophysiology : PACE · 2025

Risk of Symptomatic Pulmonary Vein Stenosis After Atrial Fibrillation Ablation With High-Power Short-Duration Approach.

СтатьяНаблюдательное исследованиеМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Palmisano Pietro, Palamà Zefferino, Bartorelli Antonio L, Bonanno Salvatore, Tricarico Giuseppe, Crea Pasquale, Coluccia Giovanni

Аннотация

BACKGROUND: Symptomatic pulmonary vein stenosis (sPVS) is a rare but severe complication of transcatheter atrial fibrillation (AF) ablation. High-power, short-duration (HPSD) and very HPSD (vHPSD) approaches for radiofrequency (RF) AF ablation have been shown to improve procedural efficiency, with effectiveness and a short-term safety profile comparable to conventional standard-power long-duration (SPLD) ablation. Findings from some previous reports suggest that HPSD may be a risk factor for the development of sPVS. The aim of this multicenter, observational analysis was to compare the incidence of sPVS after AF ablation with HPSD, vHPSD, and SPLD.

METHODS: Data from 436 consecutive patients (63.1 ± 9.5 years, 66.5% male, 70.9% with paroxysmal AF) undergoing RF AF ablation were reviewed: 64 were ablated with HPSD, 71 with vHPSD, and 301 with SPLD. The incidence of sPVS during follow-up was assessed.

RESULTS: There were no significant differences in baseline characteristics between the three groups. During a median follow-up of 20 months, 9 cases of sPVS were identified: 7 (10.9%) in HPSD group, 1 (1.4%) in vHPSD group, and 1 (0.3%) in SPLD group (p < 0.001). The use of HPSD approach was an independent predictor of sPVS (hazard ratio, 20.226; 95% confidence interval, 20.49-164.59; p = 0.005) on multivariable analysis. Seven of 9 patients underwent percutaneous PVs angioplasty and stent implantation (3 veins in 4 patients, 2 veins in 2 patients, 1 vein in 1 patient).

CONCLUSIONS: The results of this observational analysis suggest that RF AF ablation using HPSD approach may be associated with an increased risk of sPVS.