MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.dental.2017.04.025

Медицинская библиотека · Dental materials : official publication of the Academy of Dental Materials · 2017

Biomechanical behaviour of craniofacial sutures during distraction: An evaluation all over the entire craniofacial skeleton.

Savoldi Fabio, Tsoi James K H, Paganelli Corrado, Matinlinna Jukka P

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Sutures are fibrous joints connecting the bones of the head. Despite the fundamental role played by sutures in dentofacial orthopaedics, their biomechanical properties are not completely understood. This study evaluated anatomy, biomechanics, and acoustic emission (AE) during distraction of the sutural ligament (SL).

METHODS

Seventy-two suture samples were removed from a twelve-months-old swine (Sus scrofa) head. Each volume was acquired using micro-computed tomography (μCT), and the linear interdigitation index was calculated on both planes (LIICOR and LIISAG). Mechanical testing till failure was carried at 1mm/min, and four piezoelectric sensors were used for recording of amplitude (A), duration (D), and energy (E) of AE. The relationships between interdigitation, fracture types, tensile stress (σ0), and AE were statistically analysed with non-parametric tests (α=0.05).

RESULTS

σ0 of the SL had median values of 4.0MPa, and AE were characterised by A of 49.3dB (IQR=2.2), D of 826.3μs (IQR=533.4), and E of 57,715.8 eu (IQR=439,613.5). Most of the fractures happened in the SL (46%), some within the bone (34%), and fewer were combined (19%). LIICOR had correlation with A (0.383, p=0.028), D (0.348, p=0.048), and E (0.437, p=0.011) of the AE, and σ0 had similar relationship with A (0.500, p=0.003), D (0.495, p=0.003), and E (0.579, p<0.001). Maximum energy values were different between fractures within the bone and within the SL (p=0.021).

SIGNIFICANCE: Biomechanical properties under tension of most of the sutures of the craniofacial skeleton were reported. AE provided information about the sequence of events during SL distraction, and had significant relationship with its mechanical properties. Further studies are necessary to confirm these preliminary findings, and to identify their relationship with biological processes and dentofacial treatments.

Для цитирования: Savoldi Fabio, Tsoi James K H, Paganelli Corrado, Matinlinna Jukka P. Biomechanical behaviour of craniofacial sutures during distraction: An evaluation all over the entire craniofacial skeleton.. Dental materials : official publication of the Academy of Dental Materials. 2017. DOI: 10.1016/j.dental.2017.04.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.