MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7863/jum.2004.23.11.1433

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2004

The clinical value of 3-dimensional saline infusion sonography in addition to 2-dimensional saline infusion sonography in women with abnormal uterine bleeding: work in progress.

de Kroon Cornelis D, Louwé Leonie A, Trimbos J Baptist, Jansen Frank Willem

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the clinical relevance of 3-dimensional saline infusion sonography (3D-SIS) in addition to conventional SIS in women with abnormal uterine bleeding suspected of having intrauterine abnormalities.

METHODS

All women suspected of having intrauterine abnormalities were eligible. Before 3D-SIS, conventional SIS was performed. The results of these techniques were compared with the "combined method reference standard" (hysteroscopy, endometrial sampling, and clinical follow-up in cases with normal SIS findings). Diagnostic characteristics (with 95% confidence intervals [CIs]) of 3D-SIS and SIS were calculated as well as their respective accuracy in evaluating the histologic nature, the intrauterine extension, and the location of intrauterine abnormalities. Moreover, the reliability (kappa value) and clinical relevance of 3D-SIS were assessed.

RESULTS

A total of 49 women were included, and 4 women were excluded. The positive predictive values of 3D-SIS and SIS were, respectively, 1.00 and 0.86 (95% CI, 0.72-0.99; P = .15), and the diagnostic accuracy values were 0.98 (95% CI, 0.94-1.0) and 0.91 (95% CI, 0.83-0.99; P = .08). Saline infusion sonography and 3D-SIS were equally accurate in evaluating the histologic nature, intrauterine extent, and location of intrauterine abnormalities (respective kappa values: 0.85 versus 0.93; P = .88; 0.83 versus 0.83; and 0.77 versus 0.80; P = .81). The reliability of 3D-SIS was good: intraobserver and interobserver agreement (kappa) were 0.78 and 0.72. Three women (6.7%) had the benefit of additional 3D-SIS: in these women, SIS wrongly led to a diagnosis of intrauterine abnormalities (P = .08).

CONCLUSIONS

Three-dimensional saline infusion sonography is valid and reliable in women suspected of having intrauterine abnormalities and may indeed have relevant clinical value in addition to conventional SIS.

Для цитирования: de Kroon Cornelis D, Louwé Leonie A, Trimbos J Baptist, Jansen Frank Willem. The clinical value of 3-dimensional saline infusion sonography in addition to 2-dimensional saline infusion sonography in women with abnormal uterine bleeding: work in progress.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2004. DOI: 10.7863/jum.2004.23.11.1433.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.