Drug-induced aseptic meningitis after an interlaminar lumbar epidural steroid injection.

Nguyen Trong P, Kant Ishu, Cartagena Alec, Kim Jung H

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

This case report describes a rare instance of drug-induced aseptic meningitis after an interlaminar lumbar epidural steroid injection.

CASE PRESENTATION: A 74 year-old female patient presented to the ED post-procedure day three after an L4-L5 interlaminar lumbar epidural steroid injection with fever, nausea, and vomiting. The patient had previously undergone numerous lumbar epidurals without complications and used identical medications, which included 1% lidocaine, iohexol contrast, methylprednisolone (Depo-medrol), and normal saline. Pertinent labs included a WBC of 15,000 cells/μL. Lumbar MRI revealed L4-S1 aseptic arachnoiditis. Two bone scans with Gallium and T-99 confirmed no infectious process. The patient then had a second admission months later with similar presenting symptoms and hospital course after repeating the lumbar epidural steroid injection. Lumbar MRI and CSF studies confirmed aseptic meningitis.

CONCLUSION

This patient's repeated admissions from aseptic meningitis were likely caused by irritation of the meningeal layers from a medication used during the procedure.

Для цитирования: Nguyen Trong P, Kant Ishu, Cartagena Alec, Kim Jung H. Drug-induced aseptic meningitis after an interlaminar lumbar epidural steroid injection.. Pain practice : the official journal of World Institute of Pain. 2023. DOI: 10.1111/papr.13333.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.