DOI 10.1016/j.jacc.2014.09.022
Impact of the 2014 expert panel recommendations for management of high blood pressure on contemporary cardiovascular practice: insights from the NCDR PINNACLE registry.
Аннотация
BACKGROUND
Since 2003, the Seventh Report of the Joint National Committee (JNC-7) has been the predominant guideline for blood pressure management. A 2014 expert panel recommended increasing the blood pressure targets for patients age 60 years and older, as well as those with diabetes or chronic kidney disease.
OBJECTIVES
The purpose of this study was to examine the effect of the 2014 expert panel blood pressure management recommendations on patients managed in U.S. ambulatory cardiovascular practices.
METHODS
Using the National Cardiovascular Data Registry PINNACLE Registry, we assessed the proportion of patients who met the 2003 and 2014 panel recommendations, highlighting the populations of patients for whom the blood pressure goals changed.
RESULTS
Of 1,185,253 patients in the study cohort, 706,859 (59.6%) achieved the 2003 JNC-7 goals. Using the 2014 recommendations, 880,378 (74.3%) patients were at goal. Among the 173,519 (14.6%) for whom goal achievement changed, 40,323 (23.2%) had a prior stroke or transient ischemic attack, and 112,174 (64.6%) had coronary artery disease. In addition, the average Framingham risk score in this group was 8.5 ± 3.2%, and the 10-year ASCVD risk score was 28.0 ± 19.5%.
CONCLUSIONS
Among U.S. ambulatory cardiology patients with hypertension, nearly 1 in 7 who did not meet JNC-7 recommendations would now meet the 2014 treatment goals. If the new recommendations are implemented in clinical practice, blood pressure target achievement and cardiovascular events will need careful monitoring, because many patients for whom the target blood pressure is now more permissive are at high cardiovascular risk.