ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2018

Pump in Parallel-Mechanical Assistance of Partial Cavopulmonary Circulation Using a Conventional Ventricular Assist Device.

СтатьяResearch Support, N.I.H., IntramuralНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sinha Pranava, Deutsch Nina, Ratnayaka Kanishka, He Dingchao, Peer Murfad, Kurkluoglu Mustafa, Nuszkowski Mark, Montague Erin, Mikesell Gerald, Zurakowski David, Jonas Richard

Аннотация

Mechanical assistance of systemic single ventricle is effective in pulling blood through a cavopulmonary circuit. In patients with superior cavopulmonary connection, this strategy can lead to arterial desaturation secondary to increased inferior caval flow. We hypothesized that overall augmentation in cardiac output with mechanical assistance compensates for the drop in oxygen saturation thereby maintaining tissue oxygen delivery (DO2). Bidirectional Glenn (BDG) was established in seven swine (25 kg) after a common atrium had been established by balloon septostomy. Mechanical circulatory assistance of the single ventricle was achieved using an axial flow pump with ventricular inflow and aortic outflow. Cardiac output, mean pulmonary artery pressure (PAP), common atrial pressure (left atrial pressure [LAP]), arterial oxygen saturation (SaO2), partial pressure of arterial oxygen (PaO2), and DO2 were compared between assisted and nonassisted circulation. Significant augmentation of cardiac output was achieved with mechanical assistance in BDG circulation (BDG: median [interquartile range {IQR}], 0.8 [0.9-1.15] L/min versus assisted BDG: median [IQR], 1.5 [1.15-1.7] L/min; p = 0.05). Although oxygen saturations and PaO2 trended to be lower with assistance (SaO2; BDG: median [IQR], 43% [32-57%]; assisted BDG: median [IQR], 32% [24-35%]; p = 0.07) (PaO2; BDG: median [IQR], 24 [20-30] mm Hg; assisted BDG: median [IQR], 20 [17-21] mm Hg; p = 0.08), DO2 was unchanged with mechanical assistance (BDG: median [IQR], 94 [35-99] ml/min; assisted BDG: median [IQR], 79 [63-85] ml/min; p = 0.81). No significant change in the LAP or PAP was observed. In the setting of superior cavopulmonary connection/single ventricle, the systemic ventricular assistance with a ventricular assist device (VAD) leads to increase in cardiac output. Arterial oxygen saturations however may be lower with mechanical assistance, without any change in DO2.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты