Transvaginal mesh surgery for pelvic organ prolapse--Prolift+M: a prospective clinical trial.
Аннотация
INTRODUCTION AND HYPOTHESIS: This study deals with assessment of safety, efficacy, and potential complications of Prolift+M system to correct uterovaginal prolapse.
METHODS
We analyzed a prospective cohort treated with the Gynecare PROLIFT+M mesh system between October 2008 and March 2010. A composite score that included subjective/objective cure and lack of complications was used to assess treatment success.
RESULTS
One hundred sixty-seven women (age 65.1 ± 11.2 years, BMI 29.2 ± 5.8 kg/m(2)) were treated for pelvic organ prolapse using the PROLIFT+M system. Seven anterior Prolift+M, 42 posterior Prolift+M, and 118 total Prolift+M mesh surgeries were performed in patients with stage II or greater degrees of prolapse. Mean operative time was 122.7 ± 43.9 min. Mean intraoperative blood loss was 119.4 ± 125.3 ml. Our composite success score was 72.5% (treatment failures per POP-Q stage 1.4%, perception of bulge 4.4%, erosions 3.6%, pain/dyspareunia 3.7%, incontinence 0.7%, de novo urge urinary incontinence 8.7%, voiding dysfunction 0.6%, recurrent urinary tract infection 2.2%, and anal incontinence 2.2%).
CONCLUSIONS
Prolift+M surgery is safe and effective with minimal postoperative morbidities.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.