Near-infrared spectroscopy for detection of a significant patent ductus arteriosus.

Chock Valerie Y, Rose Laura A, Mante Jeanet V, Punn Rajesh

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Near-infrared spectroscopy (NIRS) may assist with characterization of a hemodynamically significant patent ductus arteriosus (hsPDA) by measuring cerebral and renal saturation (Csat and Rsat) levels. We hypothesized that Csat and Rsat in preterm infants with an hsPDA would be decreased compared to those with no PDA or nonsignificant PDA.

METHODS

This non a-priori designed study retrospectively investigated clinical and ECHO characteristics of preterm infants <29 wk gestation who underwent routine NIRS monitoring. Logistic regression assessed association between NIRS measures and an hsPDA by ECHO.

RESULTS

Of 47 infants, 21 had a confirmed hsPDA by ECHO, 14 had a nonsignificant PDA, and 12 had no ECHO performed due to low clinical suspicion for PDA. Logistic regression adjusted for gestational age found that lower Rsat was associated with an hsPDA by ECHO (OR 0.9, 95% CI 0.83-0.98, P = 0.01). Using ROC curves, Rsat < 66% identified an hsPDA with a sensitivity of 81% and specificity of 77%, while Csat was not significant.

CONCLUSION

Low Rsat < 66% was associated with the presence of an hsPDA in the preterm infant. Csat may be preserved if cerebral autoregulation is largely intact. Bedside NIRS monitoring may reasonably increase suspicion for a significant PDA in the preterm infant.

Для цитирования: Chock Valerie Y, Rose Laura A, Mante Jeanet V, Punn Rajesh. Near-infrared spectroscopy for detection of a significant patent ductus arteriosus.. Pediatric research. 2016. DOI: 10.1038/pr.2016.148.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.