MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Tanaffos · 2021

Effect of Tubular Feeding with the Measurement of Gastric Residual Volume on Ventilator Associated Pneumonia.

Barkhordari Maedeh, Jahani Simin, Soltani Farhad, Molavynejad Shahram, Maraghi Elham

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Several measures have been taken to prevent the onset of ventilator-associated pneumonia (VAP), one of which is measuring the gastric residual volume. The purpose of this study is to compare the effect of two tube feeding methods with and without gastric residual volume measurement on VAP.

MATERIALS AND

METHODS

This clinical trial was performed on the study population of patients with endotracheal tubes hospitalized in Intensive Care Units 1 and 2 of Golestan hospital, Ahvaz, Iran. Overall, 70 patients who met the inclusion criteria were randomly divided into groups 1 and 2. Groups 1 and 2 were fed with and without measuring gastric residual volume, respectively. The incidence of pneumonia was assessed using the Modified Clinical Pulmonary Infection Score prior to the intervention and on the fifth day post- intervention. The data were analyzed by the SPSS software version 22.

RESULTS

The incidence of VAP was 9.12% in the group with gastric residual volume measurement and 7.14% in the other group. There was no significant difference between the two groups (P=0.827) regarding VAP prevalence.

CONCLUSION

Monitoring gastric residual v olume requires aspiration and repeated measurements of gastric contents, resulting in increased nursing workload. Moreover, if the gastric residual volume is high, the patient will be deprived of calorie intake and subjected to malnutrition. As a result, removing the monitoring of gastric residual volume from the care setting and focusing on interventions proven to reduce VAP can be more helpful.

Для цитирования: Barkhordari Maedeh, Jahani Simin, Soltani Farhad, Molavynejad Shahram, Maraghi Elham. Effect of Tubular Feeding with the Measurement of Gastric Residual Volume on Ventilator Associated Pneumonia.. Tanaffos. 2021.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.