Diode laser spectroscopy for noninvasive monitoring of oxygen in the lungs of newborn infants.

Svanberg Emilie Krite, Lundin Patrik, Larsson Marcus, Åkeson Jonas, Svanberg Katarina, Svanberg Sune, Andersson-Engels Stefan, Fellman Vineta

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Newborn infants may have pulmonary disorders with abnormal gas distribution, e.g., respiratory distress syndrome. Pulmonary radiography is the clinical routine for diagnosis. Our aim was to investigate a novel noninvasive optical technique for rapid nonradiographic bedside detection of oxygen gas in the lungs of full-term newborn infants.

METHODS

Laser spectroscopy was used to measure contents of oxygen gas (at 760 nm) and of water vapor (at 937 nm) in the lungs of 29 healthy newborn full-term infants (birth weight 2,900-3,900 g). The skin above the lungs was illuminated using two low-power diode lasers and diffusely emerging light was detected with a photodiode.

RESULTS

Of the total 390 lung measurements performed, clear detection of oxygen gas was recorded in 60%, defined by a signal-to-noise ratio of >3. In all the 29 infants, oxygen was detected. Probe and detector positions for optimal pulmonary gas detection were determined. There were no differences in signal quality with respect to gender, body side or body weight.

CONCLUSION

The ability to measure pulmonary oxygen content in healthy full-term neonates with this technique suggests that with further development, the method might be implemented in clinical practice for lung monitoring in neonatal intensive care.

Для цитирования: Svanberg Emilie Krite, Lundin Patrik, Larsson Marcus, Åkeson Jonas, Svanberg Katarina, Svanberg Sune, Andersson-Engels Stefan, Fellman Vineta. Diode laser spectroscopy for noninvasive monitoring of oxygen in the lungs of newborn infants.. Pediatric research. 2015. DOI: 10.1038/pr.2015.267.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.