Human reproduction (Oxford, England) · 2002
Elevated blood flow resistance in uterine arteries of women with unexplained recurrent pregnancy loss.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Habara T, Nakatsuka M, Konishi H, Asagiri K, Noguchi S, Kudo T
Аннотация
BACKGROUND: Uterine perfusion appears to regulate uterine receptivity. However, vascular changes in recurrent pregnancy loss (RPL) remain poorly studied.
METHODS: One hundred and twenty one women were enrolled into this study: normal women with sterility caused by male factor (control group: n = 72) and women with RPL (n = 49). Women with uterine anomaly, impaired glucose tolerance, abnormal thyroid function, or anti-phospholipid antibodies were excluded from the study. In the mid-luteal phase of a non-pregnant cycle, transvaginal pulsed Doppler ultrasonography of the uterine artery was performed. Uterine arterial pulsatility index (PI), endometrial thickness, serum estradiol, progesterone, and nitrite/nitrate concentrations were determined.
RESULTS: In the RPL group, the PI in the uterine artery of women with antinuclear antibodies was significantly higher than that of women without antinuclear antibodies (P < 0.05). Among women without antinuclear antibodies, the mean (+/-SD) uterine artery PI in the RPL group (2.44 +/- 0.41) was also significantly higher than in the control group (2.19 +/- 0.40; P < 0.01). The PI was inversely correlated with serum progesterone levels (r = -0.47, P < 0.01).
CONCLUSIONS: Elevated uterine arterial impedance is associated with RPL. Pulsed Doppler ultrasonography is useful in identifying women with unexplained RPL who have impaired uterine circulation.
METHODS: One hundred and twenty one women were enrolled into this study: normal women with sterility caused by male factor (control group: n = 72) and women with RPL (n = 49). Women with uterine anomaly, impaired glucose tolerance, abnormal thyroid function, or anti-phospholipid antibodies were excluded from the study. In the mid-luteal phase of a non-pregnant cycle, transvaginal pulsed Doppler ultrasonography of the uterine artery was performed. Uterine arterial pulsatility index (PI), endometrial thickness, serum estradiol, progesterone, and nitrite/nitrate concentrations were determined.
RESULTS: In the RPL group, the PI in the uterine artery of women with antinuclear antibodies was significantly higher than that of women without antinuclear antibodies (P < 0.05). Among women without antinuclear antibodies, the mean (+/-SD) uterine artery PI in the RPL group (2.44 +/- 0.41) was also significantly higher than in the control group (2.19 +/- 0.40; P < 0.01). The PI was inversely correlated with serum progesterone levels (r = -0.47, P < 0.01).
CONCLUSIONS: Elevated uterine arterial impedance is associated with RPL. Pulsed Doppler ultrasonography is useful in identifying women with unexplained RPL who have impaired uterine circulation.