DOI 10.3760/cma.j.issn.1001-9391.2019.12.014
[Determination of nitrogen oxides in the air of workplace by ion chromatography].
Аннотация
Objective
Improvement the method of nitrogen oxide sampling, analysis and detection in workplace air.
Methods
Absorption and collection with sodium carbonate-sodium bicarbonate buffer solution, analysised by ion chromatography, anion column AS23, column temperature 30 ℃.
Results
The linearity of the nitrite ion in the corresponding mass concentration range 0~90.0 μg/ml was good (Nitrogen dioxide in 0~120.0 mg/m(3)) , correlation coefficient>0.999 5. The detection limit was 0.16 μg/ml, The minimum detection concentration was 0.11 mg/m(3) with the sampling volume 7.5 L.
Conclusion
The method has good accuracy, high sensitivity, with directing injection and no pre-treatment, and can popularize in general laboratories, and can satisfy the determination of nitrogen oxides in the air of workplace.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.