MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5588/ijtld.18.0004

Медицинская библиотека · The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease · 2019

Automated chest X-ray reading for tuberculosis in the Philippines to improve case detection: a cohort study.

Philipsen R H H M, Sánchez C I, Melendez J, Lew W J, van Ginneken B

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

DetecTB (Diagnostic Enhanced Tools for Extra Cases of TB), an intensified tuberculosis (TB) case-finding programme targeting prisons and high-risk communities was implemented on Palawan Island, the Philippines.

OBJECTIVE

To evaluate the performance of TB detection based on computerised chest radiography (CXR) readings.

DESIGN

Data from 14 094 subjects were analysed from September 2012 to June 2014. All CXRs were read by a physician and by software. Individuals with TB symptoms or CXR abnormalities according to the physician underwent Xpert® MTB/RIF testing, the remaining persons were considered TB-negative (screening reference). A subset of 200 CXRs was read by an independent human reader (radiological reference). This reader also re-read a subset of the most abnormal cases as identified using the software but read as normal by the physician (discordant cases).

RESULTS

A total of 10 755 individuals were included in the analysis, 2534 of whom had a positively assessed CXR; 298 cases were Xpert-positive. Using the screening reference, the area under the receiver operating characteristic curve for software readings was 0.93 (95%CI 0.92-0.94), with a sensitivity of 0.98 (95%CI 0.97-0.99) and a specificity of 0.69 (95%CI 0.40-0.98). Based on the radiological reference, the physician performed slightly worse than the software (sensitivity, 0.82, 95%CI 0.74-0.89 and specificity, 0.87, 95%CI 0.81-0.96 vs. sensitivity, 0.83, 95%CI 0.71-0.93 and specificity, 0.87, 95%CI 0.75-0.95), although this was not statistically significant. Of the 291 discordant cases, 70% were assessed as positive, resulting in a 22% increase in TB detection when extrapolated to the full cohort.

CONCLUSION

The performance of automated CXR reading is comparable to that of the attending physicians in DetecTB, and its use as a second reader could increase TB detection.

Для цитирования: Philipsen R H H M, Sánchez C I, Melendez J, Lew W J, van Ginneken B. Automated chest X-ray reading for tuberculosis in the Philippines to improve case detection: a cohort study.. The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease. 2019. DOI: 10.5588/ijtld.18.0004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.