MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.carrev.2023.06.004

Медицинская библиотека · Cardiovascular revascularization medicine : including molecular interventions · 2023

Design and rationale of a prospective, randomized, non-inferiority trial to determine the safety and efficacy of the Biolimus A9™ drug coated balloon for the treatment of in-stent restenosis: First-in-man trial (REFORM).

Traynor Bryan P, Fitzgerald Sean, Alfonso Fernando, O'Kane Peter, Sabaté Manel, Tölg Ralph, Trevelyan Jasper, Hahn Joo-Yong, Mylotte Darren, Wöhrle Jochen, Rai Himanshu, Cortese Bernardo, Morice Marie-Claude, Schuette Diane, Copt Samuel, Oldroyd Keith G, Byrne Robert A, REFORM investigators

СтатьяПротокол клинического исследованияПеревод в очереди

Аннотация

BACKGROUND

Drug-coated balloon (DCB) angioplasty with paclitaxel-eluting devices is an established treatment for coronary in-stent restenosis (ISR). Biolimus A9™ (BA9), a sirolimus analogue with enhanced lipophilicity, may facilitate enhanced local drug delivery into vascular tissue. A novel DCB coated with Biolimus A9™ represents an alternative to traditional paclitaxel- and sirolimus-coated devices. Hence, we sought to investigate the safety and efficacy of this novel DCB in the treatment of coronary ISR.

METHODS AND

DESIGN

REFORM (NCT04079192) is a prospective, multicenter, single blind, randomized controlled trial comparing the BA9-DCB (Biosensors Europe SA, Morges, Switzerland) to the paclitaxel-coated SeQuent® Please DCB (Braun Melsungen AG, Germany) in the treatment of coronary ISR. A total of 201 patients with coronary artery disease and an indication for interventional treatment of ISR in a bare-metal stent (BMS) or drug-eluting stent (DES) have been randomized 2:1 to receive treatment with the BA9- or the paclitaxel-DCB comparator. Patients were enrolled across 24 investigational centers in Europe and Asia. The primary endpoint is percent diameter stenosis (%DS) of the target segment as assessed by quantitative coronary angiography (QCA) at 6 months. Key secondary endpoints are in-stent late lumen loss, binary restenosis, target lesion failure, target vessel failure, myocardial infarction and death at 6 months. Subjects will be followed for 24 months from enrolment.

IMPLICATIONS: The REFORM trial will seek to prove that the BA9-DCB is non-inferior to the standard paclitaxel-DCB comparator in the treatment of coronary ISR with respect to %DS at 6 months and has similar safety characteristics.

Для цитирования: Traynor Bryan P, Fitzgerald Sean, Alfonso Fernando, O'Kane Peter, Sabaté Manel, Tölg Ralph, Trevelyan Jasper, Hahn Joo-Yong, Mylotte Darren, Wöhrle Jochen, Rai Himanshu, Cortese Bernardo, Morice Marie-Claude, Schuette Diane, Copt Samuel, Oldroyd Keith G, Byrne Robert A, REFORM investigators. Design and rationale of a prospective, randomized, non-inferiority trial to determine the safety and efficacy of the Biolimus A9™ drug coated balloon for the treatment of in-stent restenosis: First-in-man trial (REFORM).. Cardiovascular revascularization medicine : including molecular interventions. 2023. DOI: 10.1016/j.carrev.2023.06.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.