Pacing and clinical electrophysiology : PACE · 2023

Clinical outcomes of subcutaneous implantable cardiac defibrillator implantation - Iran SICD registry.

Многоцентровое исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mehdinejadshani Mahdiye, Fallah Hamidreza, Kamali Farzad, Alizadeh-Diz Abolfath, Eslami Masoud, Golabchi Allahyar, Taherpour Mehdi, Shahabi Javad, Mollazadeh Reza, Madadi Shabnam, Azhari Amir, Sodagar Abdolhossein, Eftekharzadeh Mahmoud, Oraii Saeed, Fazelifar Amirfarjam, Kazemisaeed Ali, Ghorbanisharif Alireza, Dalili Mohammad, Khorgami Mohammadrafie, Heidari-Bakavoli Alireaza, Jorat Mohammadvahid, Nikoo Hossein, Kheirkhah Jalal, Saravi Mehrdad, Khodaparast Morteza, Mirzaali Mansour, Emkanjoo Zahra, Mirmasoumi Mehrdad, Sadeghian Saeed, Mokhtari Meisam, Hedayati-Goudarzi Mohammadtaghi, Haghjoo Majid

Аннотация

BACKGROUND: The subcutaneous implantable-defibrillator (S-ICD) is a relatively new alternative to the transvenous ICD system to minimize intravascular lead-related complications. This paper presents outcome of SICD implantation in patients enrolled in Iran S-ICD registry.

METHODS: Between October 2015 and June 2022, this prospective multicenter national registry included 223 patients with a standard indication for an ICD, who neither required bradycardia pacing nor needed cardiac resynchronization to evaluate the early post-implant complications and long-term follow-up results of the S-ICD system.

RESULTS: The mean age of the patients was 45 ± 17 years. The majority (79.4%) were male. Ischemic cardiomyopathy (39.5%) was the most common underlying disorder among patients selected for S-ICD implant. Most study patients (68.6%) had ICD for primary prevention of sudden cardiac death. Seven patients (3.1%) were found to have suboptimal lead positions. Six patients (2.7%) developed a pocket hematoma; all were managed medically. During a mean follow-up of 2 years, the appropriate therapy was recorded in 13% of the patients and inappropriate ICD intervention mainly due to supraventricular tachycardia in 8.9%. Pocket infection was observed in four patients (1.8%) and five patients (2.2%) died mainly due to heart failure.

CONCLUSION: S-ICDs were effective at detecting and treating both induced and spontaneous ventricular arrhythmias. Major clinical complications were rare.