Effectiveness of the conveen continence guard (a disposable vaginal device) in the treatment of complicated female stress incontinence.

Nilsson C G

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Treatment alternatives for women with stress urinary incontinence, complicated by prior unsuccessful surgery or concomitant diseases that prevent surgical intervention are limited. The aim of this study was to investigate the usefulness and effectiveness of a disposable vaginal device, the Conveen Continence Guard, in cases where surgery was not recommended for treatment of stress urinary incontinence.

METHODS

Twenty-eight women, with a urodynamically proven stress urinary incontinence, were offered the use of a vaginal device during a prospective three-week treatment period. Objective and subjective prevention of urinary leakage was assessed by a 24-h pad-weighing test, by a visual analog scale and a quality of life questionnaire. At the end of the treatment period the women answered a questionnaire on the ease and comfort of use of the device.

RESULTS

Of the nineteen women who completed the study, 89.5% were cured or improved according to subjective assessments, the respective figure being 84.2% according to objective assessment.

CONCLUSION

The Conveen Continence Guard seems to be a promising treatment alternative for women for whom other treatment methods have failed. The device was well tolerated by the women and was regarded easy to use.

Для цитирования: Nilsson C G. Effectiveness of the conveen continence guard (a disposable vaginal device) in the treatment of complicated female stress incontinence.. Acta obstetricia et gynecologica Scandinavica. 2000.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.