MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2021.09.004

Медицинская библиотека · The Journal of arthroplasty · 2021

Mid-Term Results After 517 Primary Total Hip Arthroplasties With a Shortened and Shoulderless Double-Taper Press-Fit Stem: High Rates of Aseptic Loosening.

Wagner Moritz, Schönthaler Hannes, Endstrasser Franz, Dammerer Dietmar, Nardelli Paul, Brunner Alexander

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Shorter double-taper stems with reduced lateral shoulders facilitate implantation via the muscle-sparing direct anterior approach and are becoming increasingly popular. We observed an unusually high number of cases of aseptic loosening with the use of a modified stem. Therefore, the aim of this prospective single-center study was to assess safety and efficacy of this cementless stem.

METHODS

A total of 486 consecutive patients receiving 517 primary total hip arthroplasties using the MonoconMIS stem were prospectively followed up for a mean period of 5.29 years (standard deviation [SD], 1.47). Surgical and clinical data, complications, and revision surgeries were analyzed. The Western Ontario and McMaster Universities Arthritis Index (WOMAC) score was recorded before surgery and at one year and five years after surgery.

RESULTS

The overall 5-year implant survival rate was 95.2%. The individual component survival rates were 96.1% for the stem, 99.4% for the acetabular cup, and 99.0% for the isolated mobile component exchange. The most common reasons for revision were periprosthetic fracture (1.5%), aseptic stem loosening (1.4%), and infection (1.0%). The WOMAC score improved significantly from 49.57 (SD, 21.42) at baseline to 13.33 (SD, 16.47) at one year and 9.84 (SD, 14.45) at five years after surgery. Aseptic stem loosening occurred only in patients with Dorr type A proximal femur morphology.

CONCLUSION

The evaluated femoral stem is associated with revision rates higher than what has been reported for other implants. The WOMAC scores suggest adequate efficacy. Our data do not support the use of the MonoconMIS for primary total hip arthroplasty in patients with Dorr type A proximal femur morphology.

Для цитирования: Wagner Moritz, Schönthaler Hannes, Endstrasser Franz, Dammerer Dietmar, Nardelli Paul, Brunner Alexander. Mid-Term Results After 517 Primary Total Hip Arthroplasties With a Shortened and Shoulderless Double-Taper Press-Fit Stem: High Rates of Aseptic Loosening.. The Journal of arthroplasty. 2021. DOI: 10.1016/j.arth.2021.09.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.