MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3174/ajnr.a8040

Медицинская библиотека · AJNR. American journal of neuroradiology · 2023

Diagnostic Performance of Decubitus Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas.

Madhavan Ajay A, Cutsforth-Gregory Jeremy K, Brinjikji Waleed, Bathla Girish, Benson John C, Diehn Felix E, Eckel Laurence J, Mark Ian T, Morris Pearse P, Payne Melissa A, Verdoorn Jared T, Weber Nikkole M, Yu Lifeng, Baffour Francis, Fletcher Joel G, McCollough Cynthia H

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: CSF-venous fistulas are a common cause of spontaneous intracranial hypotension. Lateral decubitus digital subtraction myelography and CT myelography are the diagnostic imaging standards to identify these fistulas. Photon-counting CT myelography has technological advantages that might improve CSF-venous fistula detection, though no large studies have yet assessed its diagnostic performance. We sought to determine the diagnostic yield of photon-counting detector CT myelography for detection of CSF-venous fistulas in patients with spontaneous intracranial hypotension.

MATERIALS AND

METHODS

We retrospectively searched our database for all decubitus photon-counting detector CT myelograms performed at our institution since the introduction of the technique in our practice. Per our institutional workflow, all patients had prior contrast-enhanced brain MR imaging and spine MR imaging showing no extradural CSF. Two neuroradiologists reviewed preprocedural brain MRIs, assessing previously described findings of intracranial hypotension (Bern score). Additionally, 2 different neuroradiologists assessed each myelogram for a definitive or equivocal CSF-venous fistula. The yield of photon-counting detector CT myelography was calculated and stratified by the Bern score using low-, intermediate-, and high-probability tiers.

RESULTS

Fifty-seven consecutive photon-counting detector CT myelograms in 57 patients were included. A single CSF-venous fistula was definitively present in 38/57 patients. After we stratified by the Bern score, a definitive fistula was seen in 56.0%, 73.3%, and 76.5% of patients with low-, intermediate-, and high-probability brain MR imaging, respectively.

CONCLUSIONS

Decubitus photon-counting detector CT myelography has an excellent diagnostic performance for the detection of CSF-venous fistulas. The yield for patients with intermediate- and high-probability Bern scores is at least as high as previously reported yields of decubitus digital subtraction myelography and CT myelography using energy-integrating detector scanners. The yield for patients with low-probability Bern scores appears to be greater compared with other modalities. Due to the retrospective nature of this study, future prospective work will be needed to compare the sensitivity of photon-counting detector CT myelography with other modalities.

Для цитирования: Madhavan Ajay A, Cutsforth-Gregory Jeremy K, Brinjikji Waleed, Bathla Girish, Benson John C, Diehn Felix E, Eckel Laurence J, Mark Ian T, Morris Pearse P, Payne Melissa A, Verdoorn Jared T, Weber Nikkole M, Yu Lifeng, Baffour Francis, Fletcher Joel G, McCollough Cynthia H. Diagnostic Performance of Decubitus Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas.. AJNR. American journal of neuroradiology. 2023. DOI: 10.3174/ajnr.a8040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.